Dab tsi yog qhov qhuav-hom transformer?
Lub tshuab ziab khaub ncaws qhuav, tseem hu ua cam khwb cia resin transformer, yog ib qho khoom siv hluav taws xob uas tsis muaj kua thiab ua haujlwm feem ntau los ntawm cua txias. Nws tsis muaj qhov sib hloov thiab yog li feem ntau muaj kev nyab xeeb dua.
Lub hauv paus ntsiab lus ua haujlwm ntawm lub tshuab ziab khaub ncaws qhuav yog ua raws li electromagnetic induction. Lub input voltage generates ib magnetic teb los ntawm ib lub kauj, uas induces ib tug voltage nyob rau hauv lwm lub kauj, yog li nce los yog txo qhov voltage. Tsis zoo li cov kua transformers, qhuav transformers cia siab rau cua txias, yog li lawv yuav tsum tau muab tso rau hauv ib tug zoo-ventilated ib puag ncig kom ntseeg tau tias cov coils muaj peev xwm dissipate tshav kub.
Hom transformer no yog siv dav hauv kev lag luam xws li kev tsim kho, kev lag luam thiab kev tsim vaj tsev hauv nroog vim nws cov yam ntxwv zoo ib puag ncig (tsis muaj roj, tsis muaj roj tso tawm).
Cov txiaj ntsig ntawm JSYW 2000 kva Qhuav hom Transformers
Jiangsu Yawei 2000 kva qhuav hom transformers tau ntse xa tawm mus rau ntau lub tebchaws suav nrog Tebchaws Meskas, Canada, Panama, Venezuela, Uzbekistan, Australia, thiab Bulgaria.


Peb muaj peev xwm tsim tau txaus los xyuas kom meej tias cov khoom tuaj yeem xa tuaj raws sijhawm. Peb muaj cov kws tshaj lij tom qab-muag pab pawg thoob ntiaj teb, uas ua kom muaj kev daws teeb meem sai thiab daws txhua yam teeb meem koj yuav ntsib.

Txawm hais tias koj yog ib lub tuam txhab hluav taws xob, transformer distributor, lossis builder, koj tuaj yeem yuav JiangsuYawei lub zog transformer nrog kev ntseeg siab, paub tias koj tab tom nqis peev rau cov khoom lag luam txhim khu kev qha thiab muaj koob npe. Kawm paub txog kev ua tau zoo thiab kev ntseeg siab ntawm JiangsuYawei Transformer tailored kom tau raws li koj cov kev xav tau tshwj xeeb.

JSYW Qhuav hom Transformer khoom
●Self-extinguishing, tsis tshua muaj hluav taws kub txaus ntshai:Peb 2000 kva qhuav-hom transformers yog ua los ntawm cov ntaub ntawv hlau refractory thiab cam khwb cia resin rwb thaiv tsev, uas yuav tsis ua combustion txawm nyob rau hauv kub kub, zoo heev txo qhov kev pheej hmoo ntawm hluav taws.
●Zero Oil Siv:Tsis zoo li cov kua transformers, qhuav-hom transformers tsis xav tau roj kom txias los yog rwb thaiv tsev. Qhov no tshem tawm kev txhawj xeeb txog cov roj xau los yog nchuav, txhim kho kev nyab xeeb thaum siv.
●Eco-friendly thiab nyab xeeb:Cov tshuab ziab khaub ncaws qhuav siv cov ntaub ntawv tsis muaj tshuaj lom cov khoom siv rwb thaiv tsev. Lawv tsis tso cov pa phem lossis cov pa phem thaum ua haujlwm thiab tuaj yeem siv tau zoo nyob hauv tsev thiab sab nraum zoov.
●Tsawg nqi installation thiab qis load poob:Cov tshuab ziab khaub ncaws qhuav feem ntau tsis tshua kim rau nruab dua li cov kua hloov pauv vim tsis muaj roj thiab tsis tas yuav tsum muaj cov qauv sib khi ntxiv. Nyob rau tib lub sijhawm, lawv tuaj yeem txo qhov poob qis thiab ua kom lub zog xa hluav taws xob ntau dua.
●Kev kho qis:Qhuav hom transformers yog ruggedly tsim tsis muaj qhov txav, ua rau lawv txhim khu kev qha thiab xav tau kev saib xyuas tsawg. Kev tshuaj xyuas ib ntus feem ntau yog txaus, txo qhov kev xav tau ntawm kev kho ntau zaus.
●Sustainable:Cov tshuab ziab khaub ncaws qhuav tsis tso siab rau cov kua dej tsis zoo thiab muaj lub neej ua haujlwm ntev dua li cov tshuab hloov pauv, ua rau lawv xaiv ib puag ncig zoo.
Parameters ntawm qhuav hom transformer
Cov ntaub ntawv ntawm SCB13 series 10kV epoxy-resin rwb thaiv tsev qhuav-hom transformer
|
Rated Peev Xwm (kVA) |
Voltage ua ke |
Vector - pab pawg |
Tsis muaj load poob (w) |
Load poob nyob rau hauv txawv rwb thaiv tsev kub kuj theem (w) |
Luv-circuit Impedance (%) |
||||
|
HV (kV) |
Tapping Ranges |
LV (kV) |
B (100 degree) |
P (120 degree) |
H (45 degree) |
||||
|
30 |
6 6.3 6.6 10 10.5 11 |
±5% ±2×2.5% |
0.4 |
Dyn 11 Yyn 0 |
135 |
605 |
640 |
685 |
4.0 |
|
50 |
195 |
845 |
900 |
965 |
|||||
|
80 |
265 |
1160 |
1240 |
1330 |
|||||
|
100 |
290 |
1330 |
1415 |
1520 |
|||||
|
125 |
340 |
1565 |
1665 |
1780 |
|||||
|
160 |
385 |
1800 |
1915 |
2050 |
|||||
|
200 |
445 |
2135 |
2275 |
2440 |
|||||
|
250 |
515 |
2330 |
2485 |
2665 |
|||||
|
315 |
635 |
2945 |
3125 |
3355 |
|||||
|
400 |
705 |
3375 |
3591 |
3850 |
|||||
|
500 |
835 |
4130 |
4390 |
4705 |
|||||
|
630 |
965 |
4975 |
5290 |
5660 |
|||||
|
630 |
935 |
5050 |
5365 |
5769 |
6.0 |
||||
|
800 |
1095 |
5895 |
6265 |
6715 |
|||||
|
1000 |
1275 |
6885 |
7315 |
7885 |
|||||
|
1250 |
1505 |
8190 |
8720 |
9335 |
|||||
|
1600 |
1765 |
9945 |
10555 |
11320 |
|||||
|
2000 |
2195 |
12240 |
13005 |
14005 |
|||||
|
2500 |
2590 |
14535 |
15455 |
16605 |
|||||
|
1600 |
1765 |
11050 |
11660 |
12510 |
8.0 |
||||
|
2000 |
2195 |
13520 |
14360 |
15400 |
|||||
|
2500 |
2950 |
15980 |
17000 |
18260 |
|||||
Daim ntawv thov ntawm 2000 kva Qhuav hom Transformer
Peb 30-2500kva qhuav-hom transformers yog tsim rau kev lag luam, kev lag luam thiab kev siv hluav taws xob. Qhov no yog vim hais tias lawv tuaj yeem ua tau raws li qhov xav tau me me thiab nruab nrab voltage.
Youtube



Cim npe nrov: 2000 kva 2000 kva Qhuav hom Transformers, Tuam Tshoj 2000 kva 2000 kva qhuav hom Transformers manufacturers, lwm tus neeg, Hoobkas







