Fais fab Transformer
Peb lub hom phiaj yog los ua koj tus khub tiag tiag hauv thaj chaw ntawm lub thawv hom substation Tuam Tshoj. Jiangsu Yawei Transformer Co., Ltd. yog nyob rau hauv Hai'an City, Jiangsu Province, Suav. Peb yog cov chaw tsim khoom ntawm lub zog hloov hluav taws xob thiab cov khoom siv hluav taws xob siab -voltage equipmen. Peb lub lag luam thoob ntiaj teb ua rau peb nyob ntawm qhov tseem ceeb ntawm cov neeg siv khoom xav tau thiab cov kev daws teeb meem.Los ntawm kev tsim khoom, tsim, tsim khoom rau kev tsim khoom thiab kev sim, pab pawg Yawei nruj me ntsis tswj txhua txheej txheem.
Vim li cas thiaj xaiv peb
Peb Cov Ntawv Pov Thawj
Peb lub tuam txhab muaj ntau yam khoom tau txais IEC, CSA, UL thiab lwm yam ntawv pov thawj.
Cov khoom lag luam
Lub khw muag khoom tseem ceeb rau cov khoom lag luam yog North America, South America, Europe thiab "Belt and Road" lub teb chaws.
Khoom siv
Peb cov khoom feem ntau suav nrog transformers, mobile substations, transformer roj tso tsheb hlau luam, radiators, thiab electromagnetic xov hlau. Cov khoom yog siv nyob rau hauv lub teb chaws hwj chim daim phiaj, tsheb thauj mus los, nroog tsim, petrochemicals thiab lwm qhov chaw.
Cov khoom siv ntau lawm
Peb lub tuam txhab cov cuab yeej tsim khoom suav nrog cov tshuab tsis siv neeg stacking, SDRI slitting tshuab, tsis siv neeg winding tshuab, kab rov tav winding tshuab, ntsug winding tshuab, hluav taws xob tiv thaiv cov cuab yeej, tsis siv neeg sib dhos scaffolding, low-voltage winding machines, hydraulic presses, modern laboratory, dust-free workshops, etc.
Qhov zoo ntawm Fais fab Transformer
Nce los yog down voltage theem
Ib qho ntawm qhov zoo tshaj plaws yog lub peev xwm los nce lossis nqis voltage, ua kom muaj zog xa hluav taws xob mus ntev. Qhov no txo cov hluav taws xob poob thiab qhov hluav taws xob poob, ua kom lub zog ruaj khov thiab txhim khu kev qha kom kawg - cov neeg siv.
Tiv thaiv cov khoom siv hluav taws xob
Los ntawm kev tswj cov qib voltage, lub zog hloov hluav taws xob kuj tseem tiv thaiv cov khoom siv hluav taws xob los ntawm kev puas tsuaj los ntawm kev hloov pauv hluav taws xob, ncua lawv txoj sia thiab txo cov nqi kho.
Sib npaug reactive zog
Fais fab transformers txhim khu kev ua tau zoo tag nrho ntawm daim phiaj hluav taws xob los ntawm kev txhim kho lub zog hloov kho. Lawv pab sib npaug lub zog reactive, uas yog qhov tseem ceeb rau kev ua tiav kev siv lub zog zoo.
Txhim kho zog efficiency
Qhov no ua rau txo qis zog nkim thiab txhim kho lub zog efficiency. Fais fab transformers kuj tseem ua rau lub zog ruaj khov dua los ntawm kev muab cov kev tswj hluav taws xob thiab ua kom muaj lub zog sib xws, txawm tias lub sijhawm xav tau siab tshaj plaws.
Hom Fais Fab Transformers
Kauj ruam- nce thiab nqis - transformers
Cov transformers no yog siv los nce lossis txo qhov voltage ntawm AC mov. Ib kauj ruam- nce transformer muaj ntau lem nyob rau hauv lub thib ob winding tshaj nyob rau hauv thawj winding, thaum lub kauj ruam - down transformer muaj tsawg lem nyob rau hauv lub thib ob winding tshaj nyob rau hauv thawj winding.
Tib-theem thiab peb-theem transformers
Cov transformers no yog siv los lis ib qho -theem lossis peb-theem AC khoom. Ib qho -theem transformer muaj ib tug thawj winding thiab ib tug thib ob winding, thaum ib tug peb -theem transformer muaj peb lub ntsiab windings thiab peb theem nrab windings uas txuas nrog lub hnub qub los yog delta configuration.
Ob -winding thiab autotransformers
Cov transformers no muaj ob qho kev sib cais los yog ib qho kev sib tw rau ob qho tib si thawj thiab theem nrab. Ib tug ob-winding transformer yog siv thaum qhov voltage piv ntau dua 2, thaum lub autotransformer siv thaum qhov voltage piv tsawg dua 2.
Distribution thiab fais fab transformers
Cov transformers no yog siv rau ntau lub hom phiaj nyob rau hauv lub hwj chim system network. Lub tshuab hluav taws xob faib hluav taws xob yog siv los txo qis qhov hluav taws xob rau kev faib rau cov neeg siv khoom hauv tsev lossis kev lag luam. Nws muaj kev tswj hwm qhov hluav taws xob zoo thiab ua haujlwm ntawm kev thauj khoom tag nrho lossis ze rau tag nrho cov load feem ntau.
Cov cuab yeej transformers
Cov transformers no yog siv los ntsuas cov high voltages thiab tam sim no nyob rau hauv ib lub voj voog los ntawm kev nce lawv mus rau qis tus nqi uas tuaj yeem ntsuas los ntawm cov twj paj nruag. Lawv suav nrog tam sim no transformers (CT) thiab muaj peev xwm transformers (PT).
Roj-txias thiab qhuav- hom transformers
Cov transformers no txawv ntawm lawv txoj kev txias. Roj-cooled transformers siv cov roj ntxhia ua cov khoom cua txias uas ntws los ntawm cov hluav taws xob lossis cov khoom siv hluav taws xob. Qhuav- hom hloov pauv siv cua ua qhov nruab nrab cua txias uas ntws los ntawm qhov cua lossis kiv cua.
Core hom thiab plhaub hom transformers
Cov transformers no txawv ntawm lawv cov duab tseem ceeb thiab cov txheej txheem winding. Ib tug tub ntxhais - hom transformer muaj ib lub cores nrog ob ntsug ceg thiab ib tug kab rov tav yoke. Cov windings yog cylindrical thiab concentric thiab muab tso rau ntawm ob txhais ceg.
Sab nraum zoov vs. Sab hauv tsev Transformers
Cov transformers sab nraum zoov, tsim rau cov xwm txheej hnyav, yog cov roj- txias thiab nyob hauv cov tank hlau. Hauv qhov sib piv, cov tshuab hloov hluav taws xob sab hauv tsev ua haujlwm nyob rau hauv ib puag ncig tswj thiab feem ntau qhuav - hom, nyob rau hauv cov txee hlau.

Lub hwj chim transformer yog ib qho khoom siv uas hloov hluav taws xob ntau ntawm ib zaus mus rau lwm qhov. Nws siv lub tshuab electromagnetic los tsim ib qho chaw sib nqus hauv cov hlau coils, uas khaws cov hluav taws xob hluav taws xob thiab tom qab ntawd muab nws rov qab rau hauv daim ntawv hluav taws xob thaum lub khawm ua haujlwm qhib.
Lub hwj chim transformer yog siv nyob rau hauv National Power Grid, qhov twg hluav taws xob hloov los ntawm alternating tam sim no (AC) mus rau direct tam sim no (DC). AC hluav taws xob tuaj yeem hloov mus rau DC hluav taws xob ntawm lub tshuab hluav taws xob. Tom qab ntawd DC hluav taws xob tuaj yeem xa mus ntev los ntawm cov xov hlau lossis kab sib chaws.
Cheebtsam ntawm Fais fab Transformers
Core Components
Lub hauv paus ntawm lub transformer txhawb cov windings thiab muab ib txoj hauv kev ntawm kev tsis txaus siab rau qhov sib nqus flux. Nws yog tsim los ntawm stacking thiab laminating nyias steel los xij, uas yog insulated ntawm ib leeg los ntawm ib txheej.
Cov kev hloov pauv hauv lub zog hloov pauv
Lub windings ntawm lub transformer yog tsim los ntawm tooj liab los yog txhuas coils nrog ib tug xov tooj ntawm lem. Tooj liab feem ntau nyiam vim nws cov hluav taws xob hluav taws xob siab thiab ductility, uas txo cov khoom siv winding xav tau thiab pab yooj yim wrapping nyob ib ncig ntawm cov tub ntxhais.
Cov khoom siv insulating
Cov ntaub ntawv rwb thaiv tsev yog qhov tseem ceeb rau kev cais cov windings los ntawm cov tub ntxhais, nruab nrab ntawm thawj thiab theem nrab windings, thiab ntawm txhua qhov tig ntawm cov windings. Cov ntaub ntawv no tiv thaiv lub transformer los ntawm kev puas tsuaj.
Coj mus rhaub Changer
Kais changers yog cov cuab yeej siv los tswj lub tshuab hluav taws xob cov zis hluav taws xob los ntawm kev kho tus lej ntawm kev hloov pauv hauv ib qho winding. Qhov kev hloov pauv no hloov pauv qhov sib piv hauv cov lus teb rau qhov sib txawv input voltages thiab load tej yam kev mob.
Bushings hauv Transformers
Bushings yog cov khoom siv insulating uas pab txhawb kev sib txuas ntawm cov tam sim no - nqa conductors ntawm ib qho hluav taws xob network thiab qhov kawg ntawm transformer windings.
Transformer Tank
Lub tank transformer (los yog lub tank loj) lub tsev thiab tiv thaiv cov tub ntxhais, windings, thiab lwm yam khoom los ntawm ib puag ncig sab nraud. Nws ua haujlwm raws li lub thawv rau cov roj transformer.
Conservator Component
Lub conservator yog lub tank tso rau saum lub tank loj thiab bushings, ua lub reservoir rau roj transformer. Nws muab cov roj rau lub tank loj hauv lub transformer los ntawm cov kav dej.
Breather Component
Lub tshuab ua pa kom ntseeg tau tias cov dej noo- huab cua dawb yog muab rau tus neeg saib xyuas los ntawm huab cua los ntawm lub txaj ntawm silica gel nyob rau hauv lub thawv cylindrical. Lub silica gel ua hauj lwm raws li lub tshuab lim cua, tswj thiab txo cov dej noo hauv ob lub conservator thiab lub tank loj.
Txias System
Lub tshuab cua txias yog ib qho tseem ceeb ntawm cov khoom siv hluav taws xob, tsis hais cov khoom siv insulating siv li cas. Fais fab poob hauv transformers ua kom sov, uas ua rau kom qhov kub thiab txias ntawm cov windings thiab core.
Explosion Vent
Lub qhov hluav taws xob tawg yog cov yeeb nkab hlau nrog lub diaphragm ntawm nws qhov qhib kawg, nyob rau saum lub tank conservator. Nws yog tsim los tso cov pa roj, cov roj transformer, thiab lub zog ntau dhau thaum lub sijhawm ua haujlwm sab hauv, yog li tshem tawm cov siab txaus ntshai nyob rau hauv lub transformer thiab tiv thaiv kev tawg.
Qhov chaw xaiv thiab kev npaj rau lub zog Transformer Installation
Kev siv tau
Lub tsev kawm ntawv yuav tsum tau yooj yim nkag tau los ntawm txoj kev lossis kev tsheb nqaj hlau rau kev thauj mus los thiab xa cov khoom siv hluav taws xob thiab nws cov khoom. Lub tsev kawm ntawv tseem yuav tsum muaj chaw txaus rau kev tshem tawm, tuav, nqa, thiab txav lub tshuab hloov pauv thiab nws cov khoom siv.
Foundation
Lub tsev kawm ntawv yuav tsum muaj lub hauv paus muaj zog thiab qib uas tuaj yeem txhawb nqa qhov hnyav ntawm transformer thiab nws cov roj. Lub hauv paus tseem yuav tsum tiv thaiv cov dej tsub zuj zuj hauv qab lub tshuab hloov pauv thiab muab cov chaw tso dej rau cov roj nchuav los yog xau.
Clearance
Lub tsev kawm ntawv yuav tsum muab kev tshem tawm kom txaus los ntawm lub ntiaj teb thiab lwm qhov chaw nyob rau txhua qhov chaw nyob ntawm lub transformer, xws li bushings, terminals, kais changers, thiab lwm yam.
Qhov cua
Lub tsev kawm ntawv yuav tsum muaj qhov cua txaus rau ntuj lossis yuam kom txias ntawm lub transformer. Yog tias lub tshuab hloov pauv tau teeb tsa hauv tsev, chav tsev yuav tsum muaj cov cua nkag thiab qhov hluav taws xob txaus kom ntseeg tau tias huab cua zoo. Yog tias lub tshuab hluav taws xob tau teeb tsa sab nraum zoov, nws yuav tsum tau tiv thaiv los ntawm tshav ntuj ncaj qha, los nag, daus, plua plav, thiab lwm yam.
Suab nrov
Lub tsev kawm ntawv yuav tsum txo cov suab nrov ntawm lub tshuab hloov mus rau cov chaw nyob ze lossis chaw ua haujlwm. Lub suab nrov ntawm lub transformer tuaj yeem raug txo los ntawm kev siv lub suab teeb meem, enclosures, lossis silencers.
Kev tiv thaiv hluav taws
Lub tsev kawm ntawv yuav tsum muaj kev tiv thaiv hluav taws nyob rau hauv qhov chaw los tiv thaiv los yog tswj hluav taws kub ntawm lub transformer. Cov kev ntsuas no yuav suav nrog cov tshuaj tua hluav taws, cov tshuaj tua hluav taws, lub tswb nrov, hluav taws kub, thiab lwm yam.
FAQ
Peb paub zoo-paub tias yog ib qho ntawm cov tuam txhab hluav taws xob transformer thiab cov muag khoom hauv Suav teb. Thov koj xav tias dawb mus yuav customized fais fab transformer ntawm tus nqi sib tw los ntawm peb lub hoobkas. Tiv tauj peb kom paub meej ntxiv.









