Fais fab Transformers

• Mus txog 240MVA
• Generator Step-Up Transformers (Txuas Ntxiv Thiab Nuclear)
• Transformers Network Transformers
• Distribution me thiab nruab nrab Transformers
• Transformers Lwm yam tshaj Standard Specifications kuj raug tsim raws li cov neeg thov.
Xa kev nug

Khoom Taw qhia

Lub Fais Fab Transformer yog dab tsi?

 

Fais fab transformers yog cov cuab yeej hluav taws xob siv hauv kev xa hluav taws xob hluav taws xob los ntawm ib lub voj voog mus rau lwm qhov yam tsis hloov zaus. Lawv ua haujlwm los ntawm lub hauv paus ntsiab lus ntawm electromagnetic induction. Lawv yog siv nyob rau hauv kev xa hluav taws xob hluav taws xob ntawm lub tshuab hluav taws xob thiab kev faib cov thawj circuits.

Lub hwj chim transformer yog ib qho kev faib tawm ntawm cov transformers uas muaj qhov sib txawv ntawm qhov sib txawv ntawm 3 kv-400 kV thiab ratin saum 200 MVA. Lub voltaeratings ntawm lub hwj chim transformers muaj nyob rau hauv kev ua lag luam indlude 400 kv, 200 y, 110 ky, 66 ky, thiab 33 kv. Lwm hom kev hloov pauv muaj xws li kev faib khoom (230V-11kV) thiab ntsuas ntsuas ntsuas.

Fais fab transformers yog qhov tseem ceeb hauv kev txo qis zog poob ntau, vim joule qhov cuam tshuam, hauv kev sib kis ntawm cov hluav taws xob ntau dhau los ntawm kev hloov mus rau hauv high-voltape tam sim no ces nqis mus rau qhov kev nyab xeeb qis-voltape tam sim no. Lawv feem ntau pom muaj nyob rau hauv cov chaw tsim hluav taws xob, cov nroj tsuag kev lag luam, thiab cov tuam txhab hluav taws xob hluav taws xob.

Cov txiaj ntsig ntawm JSYW Fais Fab Transformers

 

JiangsuYawei transtormers tau ua tiav xa tawm mus rau severa lub teb chaws suav nrog United Stotes, Canada, Panama, Venezuela, Uzbekistan, Australia, thiab Bulgaria.

 

product-1000-750product-1000-532

 

Peb muaj peev xwm tsim tau txaus los xyuas kom meej tias cov khoom tuaj yeem xa tuaj raws sijhawm. Peb muaj cov kws tshaj lij tom qab-muag pab pawg thoob ntiaj teb, qhov no ua kom muaj teeb meem sai sai thiab daws teeb meem ntawm txhua yam koj yuav ntsib.

 

product-1000-750

 

Txawm hais tias koj yog ib lub tuam txhab hluav taws xob, transformer distributor, lossis builder, koj tuaj yeem yuav JiangsuYawei lub zog hloov hluav taws xob nrog kev ntseeg siab, paub tias koj tab tom nqis peev rau cov khoom lag luam txhim khu kev qha thiab muaj npe nrov.Ua tau zoo thiab kev ntseeg siab ntawm JiangsuYawei Transtormer tailored kom tau raws li koj cov kev xav tau tshwj xeeb.

 

product-1000-693

 

JSYW Fais Fab Transformer Khoom

 

JSYW Fais Fab Transformer cov khoom lag luam yog cov khoom siv hluav taws xob zoo tshaj plaws uas muab kev pabcuam txhim khu kev qha rau cov neeg siv khoom. Lub transformer yog tsim los ntawm high-quality raw khoom procured los ntawm cov neeg muag khoom muaj npe nrov tshaj plaws hauv kev lag luam.

Ob peb nta xws li installation yooj yim thiab tsis tshua muaj nqi saib xyuas kom ua tau zoo nyob rau hauv cov huab cua tsis zoo rau lub sij hawm ntev. Nov yog qee yam ntawm JSYW fais fab transformer khoom.

 

Parameters ntawm Fais fab Transformer

 

Rated Peev xwm (kVA)

Voltage ua ke

vector-pab pawg

Tsis muaj load poob (kw)

Load poob (kw)

75 degree

Tsis muaj load tam sim no (%)

Short-circuit Impendance

HV (kV)

LV (kV)

6300

110±8×1.25%

6.3

6.6

10.5

11

YNd 11

10.0

36

0.80

10.5

8000

12.0

45

0.80

10000

14.2

53

0.74

12500

16.8

63

0.74

16000

20.2

77

0.69

20000

24.0

93

0.69

25000

28.4

110

0.64

31500

33.8

133

0.64

40000

40.4

156

0.58

50000

47.8

194

0.58

63000

56.8

234

0.52

 

Daim ntawv thov ntawm Fais fab Transformer

 

Fais fab transformers siv nyob rau hauv hluav taws xob tsim thiab faib

Siv los txo cov hluav taws xob poob thaum hluav taws xob xa hluav taws xob

Lawv nyiam nyob rau hauv cov ntaub ntawv uas lub load yuav tsum tau khiav ntawm tag nrho cov peev xwm 24 × 7.

Nws yog siv nyob rau hauv high voltage step-up thiab step-down.

 

Youtube

 