Qhuav hom Transformer
Peb lub hom phiaj yog los ua koj tus khub tiag tiag hauv thaj chaw ntawm lub thawv hom substation Tuam Tshoj. Jiangsu Yawei Transformer Co., Ltd. yog nyob rau hauv Hai'an City, Jiangsu Province, Suav. Peb yog cov chaw tsim khoom ntawm lub zog hloov hluav taws xob thiab cov khoom siv hluav taws xob siab -voltage equipmen. Peb lub lag luam thoob ntiaj teb ua rau peb nyob ntawm qhov tseem ceeb ntawm cov neeg siv khoom xav tau thiab cov kev daws teeb meem.Los ntawm kev tsim khoom, tsim, tsim khoom rau kev tsim khoom thiab kev sim, pab pawg Yawei nruj me ntsis tswj txhua txheej txheem.
Vim li cas thiaj xaiv peb
Peb Cov Ntawv Pov Thawj
Peb lub tuam txhab muaj ntau yam khoom tau txais IEC, CSA, UL thiab lwm yam ntawv pov thawj.
Cov khoom lag luam
Lub khw muag khoom tseem ceeb rau cov khoom lag luam yog North America, South America, Europe thiab "Belt and Road" lub teb chaws.
Khoom siv
Peb cov khoom feem ntau suav nrog transformers, mobile substations, transformer roj tso tsheb hlau luam, radiators, thiab electromagnetic xov hlau. Cov khoom yog siv nyob rau hauv lub teb chaws hwj chim daim phiaj, tsheb thauj mus los, nroog tsim, petrochemicals thiab lwm qhov chaw.
Cov khoom siv ntau lawm
Peb lub tuam txhab cov cuab yeej tsim khoom suav nrog cov tshuab tsis siv neeg stacking, SDRI slitting tshuab, tsis siv neeg winding tshuab, kab rov tav winding tshuab, ntsug winding tshuab, hluav taws xob tiv thaiv cov cuab yeej, tsis siv neeg sib dhos scaffolding, low-voltage winding machines, hydraulic presses, modern laboratory, dust-free workshops, etc.
Peb qhov project tshiab

Txhim khu kev ruaj ntseg thiab ib puag ncig phooj ywg
Ib qho ntawm qhov zoo tshaj plaws ntawm lub tshuab hluav taws xob qhuav yog nws cov yam ntxwv muaj kev nyab xeeb. Tsis muaj cov kua nplaum uas muaj hluav taws kub, qhov kev pheej hmoo ntawm hluav taws yuav txo qis. Qhov no tsis tsuas yog ua kom muaj kev nyab xeeb ntawm cov neeg ua haujlwm tab sis kuj txo qis kev puas tsuaj rau cov cuab yeej muaj txiaj ntsig hauv kev lag luam.

Kev ntseeg siab nyob rau hauv Kev Sib Tw Ib puag ncig
Kev lag luam feem ntau ua haujlwm hauv cov xwm txheej nyuaj uas xav tau cov cuab yeej muaj zog thiab txhim khu kev qha. Ib hom qhuav transformer ua tau zoo nyob rau hauv qhov chaw zoo li no vim nws qhov kev sib khi thiab rugged. Lawv tsis tshua muaj kev cuam tshuam rau cov kab mob sab nraud, ua kom lub neej ua haujlwm ntev dua thiab txo cov kev tu ncua.

Efficiency hauv Kev Siv Chaw
Hauv kev lag luam chaw uas qhov chaw feem ntau yog tus nqi qis, kev tsim qauv ntawm cov tshuab ziab khaub ncaws qhuav dhau los ua kev ua si - hloov pauv. Cov transformers no paub txog lawv qhov chaw ua haujlwm tau zoo, tso cai rau kev hloov pauv yooj yim hauv thaj chaw uas muaj kev txwv tsis pub dhau. Qhov no tshwj xeeb tshaj yog muaj txiaj ntsig zoo rau kev lag luam uas optimizing pem teb qhov chaw yog qhov tseem ceeb.
Kev lag luam tshuaj, roj, thiab roj
Qhuav- hom transformers yog siv los muab lub zog rau ntau yam khoom siv thiab cov txheej txheem uas muaj cov khoom siv hluav taws xob lossis cov khoom tawg, xws li refineries, petrochemical nroj tsuag, kav dej, offshore platforms, thiab lwm yam.
Environmentally sensitive thaj chaw
Qhuav- hom transformers yog siv los tiv thaiv ib puag ncig los ntawm cov roj nchuav los yog cov xau uas tuaj yeem paug cov dej, av, lossis cov tsiaj qus, xws li thaj chaw tiv thaiv dej, hav zoov, hav dej, thiab lwm yam.
Hluav taws kub- thaj chaw muaj kev pheej hmoo
Qhuav- hom transformers yog siv los tiv thaiv hluav taws kub los yog txo qhov hluav taws kub puas tsuaj nyob rau hauv cov cheeb tsam uas muaj hluav taws kub hnyiab los yog muaj kev tswj hluav taws nruj, xws li hauv tsev substations, underground substations, tsev kho mob, tsev kawm ntawv, tsev so, khw malls, thiab lwm yam.
Kev tsim dua tshiab
Qhuav- hom transformers yog siv los txuas cov khoom siv hluav taws xob txuas ntxiv mus rau daim phiaj lossis rau cov khoom thauj, xws li cua turbines, hnub ci vaj huam sib luag, cov nroj tsuag dej, thiab lwm yam.
Lwm daim ntawv thov
Qhuav- hom transformers kuj tseem siv rau hauv lwm daim ntawv thov uas xav tau kev ua haujlwm siab, kev saib xyuas qis, lossis cov yam ntxwv tshwj xeeb, xws li cov tshuab traction, marine systems, mining systems, data centers, etc.
Installation Requirements ntawm qhuav hom Transformer
Sab nraum zoov qhuav hom transformer tuaj yeem ntsia tau rau hauv av lossis hauv kab. Lub peev xwm ntawm transformer ntawm 315kVA lossis tsawg dua tuaj yeem ntsia tau rau ntawm kab. Lub peev xwm ntawm ntau tshaj 315kVA yuav tsum tau muab tso rau hauv av.
Environmental tej yam kev mob:
Qhuav hom transformer nyob rau hauv sab nraum zoov siv yuav tsum tau raws li nram no ib puag ncig tej yam kev mob: qhov siab tshaj tsis tshaj 1000 meters. ambient kub: siab tshaj kub +40 degree, siab tshaj plaws txhua hnub nruab nrab kub +30 degree, siab tshaj plaws txhua xyoo nruab nrab kub +20 degree, yam tsawg kawg nkaus sab nraum zoov kub -30 degree, yam tsawg kawg nkaus hauv tsev kub -5℃. Tsis txhob los nag, av noo, kub, kub kub los yog ncaj qha tshav ntuj. Qhov kev ncua deb ntawm cov cua kub dissipation qhov cua thiab cov khoom nyob ib puag ncig yuav tsum tsis pub tsawg tshaj 40cm .
Kem installation:
Qhov kev ncua deb hauv qab yuav tsum tsis pub tsawg tshaj 2.5 meters, qhov nyob ntawm qhov av yuav tsum tsis pub tsawg tshaj 3.5 meters. Lub transformer nyob rau hauv kem yuav tsum tau ntsia tsis tu ncua thiab khov kho.
Hauv av installation:
Nws yuav tsum tau nruab rau ntawm lub cement platform uas muaj peev xwm txaus thiab qhov siab ntawm 0.5 meters. Cov laj kab yuav tsum tau teeb tsa nyob ib ncig ntawm lub transformer. Qhov siab ntawm lub laj kab yuav tsum tsis pub tsawg dua 1.7 meters thiab cov cim ceeb toom yuav tsum tau dai rau hauv qhov pom tseeb. Lub laj kab yuav tsum tsis pub tsawg dua 1 meter los ntawm cov txheej txheem transformer. Thiab nyob rau hauv cov kev taw qhia ntawm kev khiav hauj lwm, qhov deb yuav tsum tsis txhob tsawg tshaj li 2 meters.


Ua ntej kev teeb tsa, nws yog ib qho tseem ceeb uas yuav tsum tau ua ib qho me me - kev nyab xeeb ntawm ib puag ncig, uas yog, kaw lub voj voog ib ntus hauv cheeb tsam los ntawm kev hloov, thiab tsim kom muaj kev nyab xeeb tsis muaj hluav taws xob rau tus neeg teb xov tooj ua ntej kev teeb tsa tuaj yeem nqa tawm. Qhov no yog qhov tseem ceeb. Hluav taws xob tsis tuaj yeem ntsia tau.
Nyob rau tib lub sij hawm, thaum lub sij hawm installation txheej txheem, them sai sai mus rau ib tug saj zawg zog hloov nyob rau hauv lub tiag tiag daim ntawv thov ntawm lub transformer. Piv txwv li, yog tias qhuav- hom hluav taws xob hloov hluav taws xob siv ib leeg thiab hauv pab pawg, lawv txoj kab sib txawv. Koj yuav tsum nruab lawv raws li qhov xwm txheej tiag tiag. Qhov xwm txheej los rub txoj hlua.
Tsis tas li ntawd, nws tsis tuaj yeem siv tam sim ntawd tom qab kev teeb tsa tiav. Tab sis cov khoom siv hluav taws xob me me yuav tsum tau siv rau kev sim, thiab cov khoom siv hluav taws xob thiab cov khoom siv hluav taws xob qhuav ntawm -hom fais fab transformer yuav tsum tau sim nrog tus cwj mem capacitor.
Tom qab ncav cuag tus txheej txheem kev ua tau zoo, lub installation yog qhov qub, thiab kev ua haujlwm zoo li qub, tag nrho cov kev teeb tsa tuaj yeem xaus. Thov xyuam xim tiv thaiv nws thaum siv.
Manufacturing txheej txheem ntawm qhuav hom Transformer
Tsim Phase
Kev txheeb xyuas cov neeg siv khoom xav tau thiab kev txiav txim siab tshwj xeeb. Transformer tsim, nrog rau kev tsim hluav taws xob sib nqus, coil tsim, cua txias, thiab lwm yam. Kev npaj ntau lawm thiab cov txheej txheem ntws tawm.
Kev npaj khoom siv
Kev yuav khoom ntawm cov khoom siv raw xws li silicon steel (rau cov hlau nplaum sib nqus), cov ntaub ntawv rwb thaiv tsev, cov khoom siv coil, thiab lwm yam. Kev tshuaj xyuas zoo ntawm cov khoom siv raw kom ua raws li cov lus qhia tshwj xeeb.
Coil Manufacturing
Siv cov conductors los tsim cov transformer coils. Winding cov coils ntawm kev txhawb nqa tsim kom muaj qhov siab thiab tsis tshua muaj hluav taws xob windings. Xyuas kom cov rwb thaiv tsev ua tau zoo ntawm cov windings.
Core Manufacturing
Txiav thiab stacking silicon steel nplooj ntawv los tsim cov tub ntxhais transformer. Cov qauv tsim thiab kev tsim khoom tseem ceeb yog qhov tseem ceeb rau kev ua kom lub zog siv tau zoo.
Kev sib dhos
Sib sau cov coils thiab cores los tsim cov qauv tseem ceeb ntawm transformer. Txhim kho kev txhawb nqa thiab lwm yam khoom siv.
Kev kho rwb thaiv tsev
Siv cov kev kho rwb thaiv tsev rau tag nrho cov transformer kom ntseeg tau tias hluav taws xob rwb thaiv tsev kev ua tau zoo. Cov ntaub ntawv rwb thaiv tsev feem ntau suav nrog cov ntawv ntawv, vulcanized fiber, epoxy resin, thiab lwm yam.
Txias System Installation
Txhim kho qhov cua txias kom ntseeg tau tias muaj cua sov zoo thaum lub sijhawm ua haujlwm ntawm lub tshuab hluav taws xob. Cov tshuab cua txias tuaj yeem yog huab cua ntuj - txias lossis cua txias - txias.
Test thiab Debugging
Kev ntsuas kev ua tau zoo, suav nrog kev ntsuas hluav taws xob, kev ntsuas hluav taws xob, kev ntsuas cua txias, thiab lwm yam. Debugging lub transformer kom paub meej tias kev ua haujlwm zoo.
Ntim thiab xa khoom
Ntim cov transformer los tiv thaiv nws los ntawm kev puas tsuaj thaum thauj. Shipping cov khoom tiav rau cov neeg siv khoom. Thoob plaws hauv cov txheej txheem tsim khoom, kev tswj xyuas zoo yog qhov tseem ceeb los xyuas kom meej cov khoom kawg ua tau raws li cov qauv tsim thiab muaj kev ua tau zoo thiab kev ntseeg tau.
FAQ
Peb paub zoo-paub tias yog ib qho ntawm cov khoom siv hluav taws xob qhuav thiab cov muag khoom hauv Suav teb. Thov koj xav tias dawb mus yuav customized qhuav hom transformer ntawm tus nqi sib tw los ntawm peb lub hoobkas. Tiv tauj peb kom paub meej ntxiv.