Vim Li Cas Xaiv Peb
Peb lub Hoobkas
Peb lub Hoobkas muaj peev xwm tsim cov khoom siv hluav taws xob uas ua raws li cov qauv thoob ntiaj teb xws li IEC, IEEE, ANSI, CSA, EN, thiab lwm yam.
Khoom siv
State Grid, kev thauj mus los, kev tsim kho hauv nroog, kev lag luam petrochemical thiab lwm qhov chaw.
Peb Qhov Kev Pabcuam
24 Teev kev pabcuam online
Lub hom phiaj
Peb lub hom phiaj yog muab tib neeg ua ntej, siv zog rau kev txhim kho los ntawm kev siv thev naus laus zis, sib tw rau kev ua lag luam los ntawm kev ua tau zoo, thiab tsim cov txiaj ntsig los ntawm cov khoom lag luam.
Pab neeg tshaj lij
Pab pawg Yawei yog tsim los ntawm cov kws tshaj lij thiab cov kev paub dhau los, pab peb daws cov teeb meem ntawm cov neeg siv khoom sai.
Kev lag luam thoob ntiaj teb
Txog tam sim no, peb cov khoom siv tau raug xa tawm mus rau ntau thaj chaw xws li South America, North America, Asia, Australia, Europe, thiab Africa.
Yam khoom
Txuj: IEC60076 & SEC
Rated zaus: 50HZ / 60HZ
Kev sib txuas thiab vector pawg: Dyn11*
ambient kub: 55 degree
Max kub nce: Cov roj saum toj kawg nkaus 45 degree
Nruab nrab winding 50 degree
Hom cua txias: ONAN
HV tapping: Tawm -circuit kais hloov 5 txoj haujlwm: ± 2 × 2.5 * %
• Mus txog 240MVA
• Generator Kauj Ruam-Up Transformers (Txuas Ntxiv Thiab Nuclear)
• Transformers Network Transformers
• Distribution me thiab nruab nrab Transformers
• Transformers Lwm yam tshaj Standard Specifications kuj raug tsim raws li cov neeg thov.
Fais fab transformers yog cov khoom siv hluav taws xob tsim los hloov hluav taws xob hluav taws xob los ntawm ib lub voj voog mus rau lwm qhov yam tsis hloov qhov zaus. Lawv ua haujlwm ntawm lub hauv paus ntsiab lus ntawm electromagnetic induction thiab yog qhov tseem ceeb rau kev xa hluav taws xob ntawm cov tshuab hluav taws xob thiab cov khoom siv hluav taws xob. Fais fab transformers kho cov qib voltage hauv kev faib khoom siv los ntawm kev nce lossis nqis qis dua qhov voltage.

Dab tsi yog Cov Cheebtsam ntawm Fais Fab Transformers?
Core Components
Lub hauv paus ntawm lub transformer txhawb cov windings thiab muab ib txoj hauv kev ntawm kev tsis txaus siab rau qhov sib nqus flux. Nws yog tsim los ntawm stacking thiab laminating nyias steel los xij, uas yog insulated ntawm ib leeg los ntawm ib txheej. Txhawm rau txo qis eddy tam sim no thiab hysteresis poob, cov nplooj ntawv no feem ntau tsawg dua ib millimeter tuab thiab muaj cov ntsiab lus carbon qis dua 0.1%. Eddy tam sim no txo qis dua los ntawm kev sib tsoo cov hlau nrog silicon. Cov ntu ntsug ntawm cov tub ntxhais uas txhawb nqa lub voj voog yog hu ua cov ceg tawv, thaum cov kab rov tav uas txuas cov ceg ceg yog hu ua yokes.
Cov kev hloov pauv hauv lub zog hloov pauv
Lub windings ntawm lub transformer yog tsim los ntawm tooj liab los yog txhuas coils nrog ib tug xov tooj ntawm lem. Tooj liab feem ntau nyiam vim nws cov hluav taws xob hluav taws xob siab thiab ductility, uas txo cov khoom siv winding xav tau thiab pab yooj yim wrapping nyob ib ncig ntawm cov tub ntxhais.
Cov khoom siv insulating
Cov ntaub ntawv rwb thaiv tsev yog qhov tseem ceeb rau kev cais cov windings los ntawm cov tub ntxhais, nruab nrab ntawm thawj thiab theem nrab windings, thiab ntawm txhua qhov tig ntawm cov windings. Cov ntaub ntawv no tiv thaiv lub transformer los ntawm kev puas tsuaj. Qhov zoo tshaj plaws transformer insulators yuav tsum muaj siab dielectric zog, zoo heev mechanical zog, thiab muaj peev xwm tiv taus kub.
Cov khoom siv insulating
Cov ntaub ntawv rwb thaiv tsev yog qhov tseem ceeb rau kev cais cov windings los ntawm cov tub ntxhais, nruab nrab ntawm thawj thiab theem nrab windings, thiab ntawm txhua qhov tig ntawm cov windings. Cov ntaub ntawv no tiv thaiv lub transformer los ntawm kev puas tsuaj. Qhov zoo tshaj plaws transformer insulators yuav tsum muaj siab dielectric zog, zoo heev mechanical zog, thiab muaj peev xwm tiv taus kub.
Coj mus rhaub Changer
Kais changers yog cov cuab yeej siv los tswj lub tshuab hluav taws xob cov zis hluav taws xob los ntawm kev kho tus lej ntawm kev hloov pauv hauv ib qho winding. Qhov kev hloov pauv no hloov pauv qhov sib piv hauv cov lus teb rau qhov sib txawv input voltages thiab load tej yam kev mob. Thaum lub transformer yog offloaded, cov zis voltage nce, thaum nws txo nyob rau hauv load tej yam kev mob. Cov kais hloov pauv feem ntau txuas nrog lub siab -voltage (HV) winding kom tso cai rau kev hloov kho qhov hluav taws xob zoo thiab txo cov tub ntxhais poob. Tsis tas li ntawd, txij li tam sim no nyob rau hauv HV winding yog qis dua, qhov kev teeb tsa no pab txo qis qhov kev pheej hmoo ntawm qhov hluav taws xob thiab hluav taws xob cov roj transformer.
Bushings hauv Transformers
Bushings yog cov khoom siv insulating uas pab txhawb kev sib txuas ntawm cov tam sim no - nqa conductors ntawm ib qho hluav taws xob network thiab qhov kawg ntawm transformer windings. Feem ntau, bushing rwb thaiv tsev yog tsim los ntawm cov plooj (porcelain) lossis epoxy resin. Cov bushings yog mounted rau sab nrauv ntawm lub ntsiab transformer tank.
Transformer Tank
Lub tank transformer (los yog lub tank loj) tsev thiab tiv thaiv cov tub ntxhais, windings, thiab lwm yam khoom los ntawm ib puag ncig sab nraud. Nws ua haujlwm raws li lub thawv rau cov roj transformer. Nws yog tsim los ntawm dov steel phaj los yog txhuas ntawv.
Conservator Component
Lub conservator yog lub tank tso rau saum lub tank loj thiab bushings, ua lub reservoir rau roj transformer. Nws muab cov roj rau lub tank loj hauv lub transformer los ntawm cov kav dej. Lub conservator nta lub zais zis hloov tau yooj yim uas haum rau kev nthuav dav thiab kev cog lus ntawm cov roj, muab qhov chaw txaus rau roj expansion thaum lub sij hawm kub ambient kub. Nws yog vented rau cov huab cua los tswj cov kev hloov siab, tso cai rau huab cua nkag los yog tawm thaum cov roj nthuav dav thiab sib cog lus.
Breather Component
Lub tshuab ua pa kom ntseeg tau tias cov dej noo- huab cua dawb yog muab rau tus neeg saib xyuas los ntawm huab cua los ntawm lub txaj ntawm silica gel nyob rau hauv lub thawv cylindrical. Lub silica gel ua haujlwm ua lub lim cua, tswj thiab txo cov dej noo hauv ob lub conservator thiab lub tank loj. Lub tshuab nqus pa yog txuas nrog lub conservator ntawm lub raj xa dej.
Txias System
Lub tshuab cua txias yog ib qho tseem ceeb ntawm cov khoom siv hluav taws xob, tsis hais cov khoom siv insulating siv li cas. Fais fab poob hauv transformers ua kom sov, uas ua rau kom qhov kub thiab txias ntawm cov windings thiab core. Yog li ntawd, qhov kub ntawm cov khoom siv insulating kuj nce. Yog tias tsis muaj lub tshuab ua kom txias zoo, cov khoom no tuaj yeem raug kev puas tsuaj lossis decomposition los ntawm qhov kub thiab txias. Transformer cooling systems feem ntau suav nrog cov kiv cua, radiators, thiab cov kav dej txias. Thaum tshav kub kub yog kis los ntawm ntuj thiab / los yog yuam convection thiab hluav taws xob.
Explosion Vent
Lub qhov hluav taws xob tawg yog cov yeeb nkab hlau nrog lub diaphragm ntawm nws qhov qhib kawg, nyob rau saum lub tank conservator. Nws yog tsim los tso tawm cov pa roj, cov roj transformer, thiab lub zog ntau dhau thaum lub sijhawm ua haujlwm sab hauv, yog li tshem tawm cov siab txaus ntshai nyob rau hauv lub transformer thiab tiv thaiv kev tawg. Thaum cov kev ua txhaum sab hauv ua rau lub siab nce mus rau qhov tseem ceeb, lub qhov cua tso cai rau lub siab no tawm mus rau hauv qhov chaw, ua rau lub diaphragm tawg ntawm qhov tsis tshua muaj siab los tiv thaiv lub transformer.
Buchholz Relay
Lub Buchholz relay yog ntsia rau hauv lub raj xa dej txuas nrog lub conservator thiab lub ntsiab tank ntawm lub transformer. Nws tshawb pom qhov ua txhaum los ntawm kev hnov cov pa roj tawm thaum lub sijhawm ua txhaum cai thiab ua rau ob qho kev mus ncig thiab lub tswb. Thaum lub relay pom cov roj no, nws ua rau lub voj voog ncig mus ncig, uas ua rau lub Circuit Court breaker cuam tshuam qhov tam sim no ntws mus rau thawj winding. Cov emission gases yog tsim los ntawm lub tshav kub generated los ntawm internal faults.
Hom Fais Fab Transformers
Kauj ruam- nce thiab nqis - transformers:Cov transformers no yog siv los nce lossis txo qhov voltage ntawm AC mov. Ib kauj ruam- nce transformer muaj ntau lem nyob rau hauv lub thib ob winding tshaj nyob rau hauv thawj winding, thaum lub kauj ruam -down transformer muaj tsawg lem nyob rau hauv lub thib ob winding tshaj nyob rau hauv thawj winding.
Tib-theem thiab peb-theem transformers:Cov transformers no yog siv los lis ib qho -theem lossis peb-theem AC khoom. Ib qho -theem transformer muaj ib tug thawj winding thiab ib tug thib ob winding, thaum ib tug peb -theem transformer muaj peb thawj windings thiab peb theem nrab windings uas txuas nrog nyob rau hauv lub hnub qub los yog delta configuration.
Ob -winding thiab autotransformers:Cov transformers no muaj ob qho kev sib cais los yog ib qho kev sib tw rau ob qho tib si thawj thiab theem nrab. Ob -winding transformer yog siv thaum qhov voltage piv ntau dua 2, thaum lub autotransformer siv thaum qhov voltage piv tsawg dua .
Fais fab tuag transformers:Cov transformers no yog siv rau ntau lub hom phiaj nyob rau hauv lub hwj chim system network. Lub tshuab hluav taws xob faib hluav taws xob yog siv los txo qis qhov hluav taws xob rau kev faib rau cov neeg siv khoom hauv tsev lossis kev lag luam. Nws muaj kev tswj hwm qhov hluav taws xob zoo thiab ua haujlwm ntawm kev thauj khoom tag nrho lossis ze rau tag nrho cov load feem ntau. Lub hwj chim transformer yog siv los nce lossis nqis qis ntawm qhov hluav taws xob rau kev sib kis ntawm cov chaw tsim khoom thiab cov chaw ua haujlwm substations. Nws muaj kev tswj tsis zoo voltage thiab ua haujlwm ntawm cov khoom sib txawv raws li qhov xav tau.
Cov cuab yeej transformers:Cov transformers no yog siv los ntsuas cov high voltages thiab tam sim no nyob rau hauv ib lub voj voog los ntawm kev nce lawv mus rau qis tus nqi uas tuaj yeem ntsuas los ntawm cov twj paj nruag. Lawv suav nrog tam sim no transformers (CT) thiab muaj peev xwm transformers (PT).
Roj-txias thiab qhuav- hom transformers:Cov transformers no txawv hauv lawv txoj kev txias. Roj-cooled transformers siv cov roj ntxhia ua cov khoom cua txias uas ntws los ntawm cov hluav taws xob lossis cov khoom siv hluav taws xob. Qhuav- hom transformers siv cua ua qhov nruab nrab cua txias uas ntws los ntawm qhov cua lossis kiv cua.
Core hom thiab plhaub hom transformers:Cov transformers no txawv nyob rau hauv lawv cov duab tseem ceeb thiab winding kev npaj. Ib tug tub ntxhais - hom transformer muaj ib lub cores nrog ob ntsug ceg thiab ib tug kab rov tav yoke. Cov windings yog cylindrical thiab concentric thiab muab tso rau ntawm ob txhais ceg. Lub plhaub- hom transformer muaj lub hauv paus caj dab thiab ob sab caj npab uas tsim lub plhaub nyob ib ncig ntawm cov windings. Cov windings yog sandwiched ntawm cov ceg tawv thiab muaj ntau txheej.
Sab nraum zoov vs. Indoor Transformers:Cov transformers sab nraum zoov, tsim rau cov xwm txheej hnyav, yog cov roj- txias thiab nyob hauv cov tank hlau. Hauv qhov sib piv, cov tshuab hloov hluav taws xob sab hauv tsev ua haujlwm nyob rau hauv ib puag ncig tswj thiab feem ntau qhuav - hom, nyob rau hauv cov txee hlau.

Ib qho alternating tam sim no dhau los ntawm thawj winding. Nws tsim ib qho kev hloov magnetic teb nyob ib ncig ntawm lub transformer hlau core. Qhov no tshwm sim vim qhov sib nqus ntawm cov dej ntws tam sim no.
Raws li kev hloov hluav taws xob hloov pauv, lub zog sib nqus hauv lub zog hauv cov tub ntxhais sib txuas tau nthuav dav thaum ib nrab ntawm lub voj voog thiab tawg rov qab thaum lwm ib nrab.
Qhov no tsis tu ncua sib txawv sib nqus flux permeates los ntawm cov tub ntxhais sab hauv thiab txiav los ntawm qhov thib ob winding qhwv ib ncig ntawm tib lub tub ntxhais hlau qauv.
Raws li Faraday txoj cai ntawm electromagnetic induction, qhov hloov magnetic teb ua rau electromotive quab yuam (EMF) nyob rau hauv lub thib ob winding coils raws li cov flux txiav los ntawm nws.
Qhov loj ntawm induced EMF nyob rau hauv lub thib ob yog nyob ntawm tej yam xws li tus nqi ntawm kev hloov ntawm flux, tus naj npawb ntawm lem nyob rau hauv winding, thiab lwm yam transformer specifications.
Los ntawm kev kho tus naj npawb ntawm cov lem nyob rau hauv ob windings, qhov induced voltage nyob rau hauv lub thib ob yuav tsum tau nce los yog down txheeb ze rau thawj voltage siv lub transformer tig ratio.
Qhov hloov hluav taws xob hloov pauv no yog tom qab ntawd muaj rau kev xa hluav taws xob txuas mus ntxiv lossis kev faib cov ntawv thov tom qab dhau los ntawm kev sib cais thib ob winding.
Kev siv fais fab Transformers
Kev tsim hluav taws xob:Fais fab transformers yog siv los nce qhov voltage generated los ntawm fais fab nroj tsuag rau kis mus rau substations.
Kev xa hluav taws xob:Fais fab transformers yog siv los nce lossis nqis qis dua qhov hluav taws xob ntawm cov ntsiab lus sib txawv ntawm kev sib txuas lus sib txuas rau kev xa hluav taws xob zoo.
Lub zog faib:Fais fab transformers yog siv los txo qis voltage rau kev faib rau cov neeg siv khoom hauv tsev lossis kev lag luam. Nws ua haujlwm ntawm cov khoom sib txawv raws li qhov xav tau thiab muaj kev tswj hwm qhov hluav taws xob zoo.
Kev tsim hluav taws xob:Fais fab transformers yog siv los nce qhov voltage ntawm cov hluav taws xob tsim los ntawm cov chaw tsim hluav taws xob ua ntej nws raug xa mus rau hauv daim phiaj. Qhov no txo qhov tam sim no thiab cov kab poob thaum sib kis.
Kev xa hluav taws xob:Fais fab transformers yog siv los nce lossis nqis qis dua qhov hluav taws xob ntawm cov ntsiab lus sib txawv ntawm kev sib txuas lus sib txuas rau kev xa hluav taws xob zoo. Lawv kuj muab kev sib cais galvanic thiab impedance txuam ntawm cov circuits sib txawv.
Lub zog faib:Fais fab transformers yog siv los txo qis voltage rau kev faib rau ntau tus neeg siv khoom. Lawv kuj muab ntau theem voltage rau kev siv sib txawv, xws li teeb pom kev zoo, cua sov, cua txias, kev sib txuas lus, thiab lwm yam.
Teeb pom kev zoo:Fais fab transformers yog siv los muab cov hluav taws xob tsawg thiab cov hluav taws xob siab rau cov teeb pom kev zoo, xws li cov teeb fluorescent, cov paib neon, thiab lwm yam.
Audio systems:Fais fab transformers yog siv los cais thiab nthuav tawm suab hauv cov hais lus, amplifiers, microphones, thiab lwm yam.
Cov khoom siv hluav taws xob:Fais fab transformers yog siv los muab hluav taws xob tsawg thiab tswj fais fab rau cov khoom siv hluav taws xob, xws li khoos phis tawj, TV, xov tooj cua, thiab lwm yam.
Cov ntawv pov thawj








Peb lub Hoobkas
Los ntawm xyoo dhau los ntawm kev paub txog kev lag luam thoob ntiaj teb, peb lub Hoobkas muaj peev xwm tsim cov khoom siv hluav taws xob uas ua tau raws li ntau yam kev cai thoob ntiaj teb xws li IEC, IEEE, ANSI, CSA, EN, thiab lwm yam. Los ntawm cov khoom tsim, tsim, ntau lawm rau kev tsim khoom thiab kev sim, pawg Yawei nruj me ntsis tswj txhua txheej txheem. Txog tam sim no, peb cov khoom siv tau raug xa tawm mus rau ntau thaj chaw xws li South America, North America, Asia, Australia, Europe, thiab Africa. Txij li xyoo 1992, Yawei Transformer tau ua tiav ntau qhov haujlwm txawv teb chaws. Peb muaj kev ntseeg siab hauv kev yeej txhua qhov haujlwm, uas yuav pab tau peb cov neeg siv khoom muaj peev xwm ua tau zoo dua hauv kev lag luam thoob ntiaj teb. Rau Yawei, peb lub hom phiaj yog muab tib neeg ua ntej, siv zog rau kev txhim kho los ntawm kev siv tshuab, sib tw rau kev ua lag luam los ntawm kev ua tau zoo, thiab tsim cov txiaj ntsig los ntawm hom. Peb tsom mus rau kev txhim kho txuas ntxiv thiab siv zog rau kev txhim kho ntsuab ntawm cov khoom siv hluav taws xob. Pab pawg Yawei yog tsim los ntawm cov kws tshaj lij thiab cov kev paub dhau los, pab peb daws cov teeb meem ntawm cov neeg siv khoom sai. Txawm hais tias xaiv cov khoom tam sim no los ntawm peb cov catalog lossis nrhiav kev pabcuam engineering rau koj daim ntawv thov, thov hu rau peb lub chaw pabcuam neeg siv khoom los tham txog koj cov kev xav tau.

FAQ
Cim npe nrov: Tuam Tshoj fais fab tuag transformers manufacturers, lwm tus neeg, Hoobkas






