Ib Theem Ib Leeg Pad-Mounted Transformer yog lub compact thiab nws tus kheej- muaj cov khoom siv hluav taws xob siv rau kev hloov pauv hluav taws xob thiab kev faib tawm hauv ib qho -theem fais fab. Feem ntau tsim rau kev teeb tsa sab nraum zoov, cov hloov pauv no tau nruab rau ntawm cov pob zeb ua kom muaj kev ruaj ntseg thiab kev tiv thaiv. Lawv ua lub luag haujlwm tseem ceeb hauv kev nce qib siab - hluav taws xob hluav taws xob los ntawm cov kab hluav taws xob faib hluav taws xob kom qis qis tsim nyog rau kev siv vaj tse, kev lag luam, lossis kev lag luam. Tib -theem ncoo-mounted transformers feem ntau yog ua haujlwm nyob rau hauv nroog thiab suburban cheeb tsam uas qhov chaw xav txog thiab zoo nkauj tseem ceeb. Lawv cov qauv tsim muaj xws li cov yam ntxwv xws li cov rwb thaiv tsev siab, cov ntaub thaiv npog, thiab feem ntau suav nrog cov yam ntxwv xws li fuses, keyboards, thiab xob laim ntes rau kev txhim kho kev nyab xeeb thiab kev ua haujlwm. Cov transformers no ua rau muaj txiaj ntsig zoo thiab txhim khu kev qha ntawm cov hluav taws xob hluav taws xob hauv ntau yam kev siv, muab cov kev daws teeb meem rau kev faib hluav taws xob faib hluav taws xob.
Qhov zoo ntawm Single Phase Pad Mounted Transformer
Space -kev tsim qauv zoo
Ib qho -theem ncoo- mounted transformers yog compact thiab tsim rau sab nraum zoov kev teeb tsa, ua rau lawv qhov chaw -ntau thiab haum rau hauv nroog thiab suburban cheeb tsam qhov chaw muaj tsawg.
Yooj yim ntawm installation
Kev teeb tsa ntawm ib zaug -theem ncoo-mounted transformers yog qhov ncaj nraim. Lawv tau ua ntej- sib dhos thiab lub Hoobkas- sim, ua kom yooj yim ntawm - cov txheej txheem kev teeb tsa ntawm qhov chaw thiab txo qhov xav tau ntawm kev tsim kho.
Txo kev cuam tshuam ib puag ncig
Qhov ntim ntawm cov transformers no nyob rau hauv cov ntaub ntawv kaw cia pab tiv thaiv cov roj nchuav thiab txo qhov kev pheej hmoo ntawm ib puag ncig. Qhov kev tiv thaiv ib puag ncig no ua raws li cov qauv thiab cov kev cai niaj hnub no.
Txhim khu kev ruaj ntseg nta
Ib qho -theem ncoo- mounted transformers feem ntau tuaj nrog ua - nyob rau hauv kev nyab xeeb nta xws li fuses, keyboards, thiab xob laim ntes. Cov yam ntxwv no pab txhim kho kev nyab xeeb, tiv thaiv kev ua txhaum, thiab kev saib xyuas yooj yim.
vim li cas xaiv peb
Cov khoom tseem ceeb
Peb muab ntau yam kev hloov pauv, suav nrog cov hloov pauv loj, ib zaug -theem transformers, ncoo-mounted transformers, tis transformers, thiab mobile substations. Peb cov khoom lag luam kuj suav nrog cov twj tso kua mis transformer, radiators, thiab electromagnetic hlau.
Kev paub nplua nuj
Nrog xyoo dhau los ntawm kev tsim hluav taws xob thoob ntiaj teb, peb lub Hoobkas tsim cov tshuab hloov pauv uas ua raws li ntau yam kev cai thoob ntiaj teb xws li IEC, IEEE, ANSI, CSA, thiab EN. Pab pawg Yawei nruj me ntsis tswj txhua txheej txheem, los ntawm kev tsim khoom thiab tsim khoom mus rau kev tsim khoom thiab kev sim.
Kev Muag Khoom
Txog tam sim no, peb cov khoom siv tau raug xa tawm mus rau ntau thaj chaw, suav nrog South America, North America, Asia, Australia, Europe, thiab Africa.
Peb Cov Kev Pabcuam
Pab pawg Yawei muaj cov kws tshaj lij nrog cov kev paub dhau los, tso cai rau peb daws cov teeb meem ntawm cov neeg siv khoom sai. Txawm hais tias koj tab tom xaiv ib yam khoom los ntawm peb cov catalog lossis nrhiav kev pabcuam engineering rau koj daim ntawv thov, thov hu rau peb lub chaw pabcuam neeg siv khoom los tham txog koj cov kev xav tau.
Txoj Cai Ua Haujlwm ntawm Ib Theem Pad Mounted Transformer
Lub hauv paus ntsiab lus ntawm kev ua haujlwm ntawm Ib Phase Pad -Mounted Transformer yog raws li cov hauv paus ntsiab lus ntawm electromagnetic induction. Cov transformers no ua haujlwm ntawm lub hauv paus ntsiab lus uas hloov pauv magnetic teb induces ib tug voltage nyob rau hauv ib tug nyob ze coil. Nyob rau hauv ib zaug xwb -theem ncoo-mounted transformer, feem ntau muaj ob coils raug mob nyob ib ncig ntawm ib tug ntau yam hlau core: thawj kauj thiab lub thib ob kauj.
Thaum alternating tam sim no (AC) ntws los ntawm thawj kauj, nws tsim ib qho chaw sib nqus uas hloov cov kev taw qhia nrog cov kev hloov hauv AC waveform. Qhov no hloov magnetic teb induces ib tug voltage nyob rau hauv lub thib ob kauj los ntawm electromagnetic induction. Lub induced voltage nyob rau hauv lub thib ob kauj yog proportional rau lub lem ratio ntawm lub coils, tso cai rau lub voltage transformation.Cov tub ntxhais, feem ntau yog ua los ntawm laminated hlau los yog lwm yam khoom siv hlau nplaum, txhim khu lub sib nqus coupling ntawm lub coils, ua kom muaj zog hloov tau zoo. Lub transformer tus tsim ua kom ntseeg tau tias lub hauv paus thiab theem nrab windings yog hluav taws xob cais tawm thaum raug sib nqus sib nqus.
Cov ntaub ntawv siv nyob rau hauv ib theem Pad Mounted Transformer
Cov khoom siv tseem ceeb
Lub hauv paus ntawm lub transformer feem ntau yog ua los ntawm laminated silicon steel. Cov khoom no muab siab sib nqus permeability, txo lub zog poob thiab ua kom muaj zog sib nqus flux nyob rau hauv lub transformer.
Cua txias
Thawj thiab theem nrab windings feem ntau yog ua los ntawm tooj liab lossis txhuas conductors. Cov ntaub ntawv no muaj cov khoom siv hluav taws xob zoo thiab tsim nyog rau tam sim no - nqa cov kev xav tau ntawm transformer.
Cov ntaub ntawv insulating
Ntau yam ntaub ntawv insulating yog siv los cais thiab insulate cov khoom siv hluav taws xob, tiv thaiv hluav taws xob tawg. Rwb thaiv tsev tej zaum yuav muaj xws li cov ntaub ntawv xws li roj-impregnated ntawv, epoxy resin, los yog lwm yam advanced rwb thaiv tsev systems.
Cov ntaub thaiv npog
Lub kaw lus lossis lub tank uas nyob hauv lub tsev hloov pauv feem ntau yog ua los ntawm cov ntaub ntawv muaj zog xws li hlau lossis txhuas. Kev xaiv ntawm cov khoom ua kom muaj kev tiv thaiv ib puag ncig yam, kev cuam tshuam txhua yam, thiab corrosion.
Roj
Ntau lub ncoo-mounted transformers yog roj-immersed, thiab cov roj insulating siv feem ntau yog cov roj ntxhia lossis, qee zaum, ib puag ncig- lwm txoj hauv kev zoo li cov roj ester ntuj lossis cov khoom siv hluavtaws. Cov roj muab ob qho tib si hluav taws xob rwb thaiv tsev thiab ua kom txias txias rau lub transformer.
Bushings
Bushings, uas yog siv los txuas sab nraud conductors rau lub transformer, feem ntau yog ua los ntawm cov plooj (porcelain) los yog cov khoom sib xyaw. Cov ntaub ntawv no muab cov hluav taws xob rwb thaiv tsev zoo thiab lub zog txhua yam.
Cheebtsam ntawm Ib Theem Pad Mounted Transformer




Core
Cov tub ntxhais feem ntau yog ua los ntawm laminated silicon steel thiab muab txoj hauv kev tsis txaus siab rau qhov sib nqus flux tsim los ntawm thawj winding. Lub hauv paus tseem ceeb heev rau kev hloov hluav taws xob zoo thiab txo qis kev poob.
Thawj thiab theem nrab windings
Thawj winding tau txais cov input voltage, thaum lub thib ob winding muab cov zis voltage. Ob leeg windings muaj tooj liab los yog txhuas conductors, kom ntseeg tau tias cov hluav taws xob zoo conductivity.
Cov ntaub ntawv insulating
Ntau yam ntaub ntawv insulating yog siv los cais thiab insulate lub windings thiab lwm yam conductive Cheebtsam. Cov ntaub ntawv muaj xws li roj- daim ntawv impregnated, epoxy resin, los yog lwm yam txheej txheem rwb thaiv tsev siab heev.
Insulating roj
Hauv cov roj-immersed transformers, ib qho roj insulating, xws li cov roj ntxhia lossis ib puag ncig- lwm txoj hauv kev zoo li cov roj ester, yog siv los muab cov hluav taws xob rwb thaiv tsev thiab ua kom txias zoo.
Tank los yog enclosure
Lub tank los yog enclosures lub tsev transformer Cheebtsam, muab kev tiv thaiv tiv thaiv ib puag ncig yam, mechanical cuam tshuam, thiab ua kom muaj kev ruaj ntseg. Nws feem ntau yog ua los ntawm steel los yog txhuas.
Bushings
Bushings yog cov khoom siv insulating siv los txuas sab nraud conductors mus rau lub transformer. Lawv feem ntau yog ua los ntawm cov plooj (porcelain) lossis cov ntaub ntawv sib xyaw, muab cov hluav taws xob rwb thaiv tsev thiab cov khoom siv dag zog.
Coj mus rhaub changer
Yog tias nruab nrog tus kais hloov pauv, nws tso cai rau kho qhov hloov pauv thiab, yog li, qhov tso zis hluav taws xob. Tus kais hloov pauv feem ntau suav nrog cov neeg sib cuag thiab lub tshuab hloov pauv cov ntsiab lus sib txuas ntawm lub winding.
Cov cuab yeej siv siab
Txhawm rau tiv thaiv kom tsis txhob muaj kev kub ntxhov ntau dhau hauv lub tshuab hloov pauv, cov cuab yeej siv lub siab nyem feem ntau tau teeb tsa. Qhov kev nyab xeeb no pab tiv thaiv lub transformer los ntawm kev puas tsuaj nyob rau hauv cov ntaub ntawv ntawm sab hauv faults.
Cov txheej txheem ntau lawm ntawm Ib Theem Pad Mounted Transformer
Kev yuav khoom:Thaum tsim tau tiav lawm, cov ntaub ntawv xws li laminated silicon steel rau cov tub ntxhais, tooj liab lossis aluminium conductors rau windings, insulating cov ntaub ntawv, cov ntaub ntawv tank, thiab lwm yam khoom yog procured los ntawm cov neeg muag khoom txhim khu kev qha.
Core manufacturing:Cov ntawv laminated silicon steel raug txiav thiab muab tso rau hauv cov tub ntxhais. Tom qab ntawd cov tub ntxhais tau sib sau ua ke, kom ntseeg tau tias qhov tsawg - tsis kam sib nqus txoj hauv kev rau kev hloov hluav taws xob zoo.
Winding sib dhos:Thawj thiab theem nrab windings yog tsim los siv tooj liab lossis txhuas conductors. Cov windings tau ua tib zoo raug mob nyob ib ncig ntawm lub hauv paus, ua raws li cov qauv tsim. Cov ntaub ntawv insulating yog siv los cais cov windings thiab tiv thaiv hluav taws xob tawg.
Tank fabrication:Lub tank los yog enclosure, feem ntau yog ua los ntawm steel los yog txhuas, yog fabricated. Nws yog tsim los rau hauv tsev cov khoom siv transformer ruaj ntseg, muab kev tiv thaiv ib puag ncig yam.
Kev sib dhos ntawm cov khoom siv:Cov tub ntxhais, windings, insulating cov ntaub ntawv, thiab lwm yam khoom yog sib sau ua ke rau hauv lub tank. Kev saib xyuas yog ua kom muaj kev sib raug zoo, kev rwb thaiv tsev, thiab kev ua haujlwm zoo ntawm lub transformer.
Roj filling:Yog hais tias lub transformer yog roj -immersed, cov roj insulating yog ua tib zoo sau rau hauv lub tank. Cov roj muab hluav taws xob rwb thaiv tsev thiab ua haujlwm ua kom txias. Cov txheej txheem filling suav nrog degassing kom tshem tawm cov huab cua thiab noo noo los ntawm cov roj.
Kev kuaj:Lub transformer tau dhau kev sim nruj heev los xyuas nws cov hluav taws xob thiab kev ua haujlwm zoo. Cov kev ntsuam xyuas feem ntau suav nrog kev ntsuas lub zog dielectric, ntsuas kev tiv thaiv hluav taws xob, ntsuas qhov sib piv, thiab ntsuas kev thauj khoom. Qhov no ua kom cov transformer ua tau raws li cov qauv thiab cov qauv kev ua tau zoo.
Daim ntawv thov ntawm Single Phase Pad Mounted Transformer
Cov cheeb tsam lag luam thiab lag luam
Cov transformers no tau ua haujlwm nyob rau hauv kev lag luam thiab kev lag luam hauv cheeb tsam los pab txhawb kev faib hluav taws xob rau cov chaw ua haujlwm, khw, thiab lwm qhov chaw lag luam. Lawv qhov chaw- tsim kom muaj txiaj ntsig yog qhov muaj txiaj ntsig hauv thaj chaw uas tsis muaj chaw txaus.
Kev lag luam chaw
Cov chaw tsim khoom lag luam thiab cov chaw tsim khoom feem ntau siv Ib Phase Pad -Mounted Transformers rau kev faib hluav taws xob zoo hauv thaj chaw. Cov transformers tuaj yeem muab tso rau hauv kev ua kom tau raws li qhov tshwj xeeb ntawm cov khoom siv hluav taws xob ntawm kev lag luam.
Cov tsev kawm ntawv
Cov tsev kawm ntawv, tsev kawm qib siab, thiab tsev kawm qib siab tuaj yeem siv cov hloov pauv no rau kev faib hluav taws xob thoob plaws hauv tsev kawm ntawv. Cov transformers muaj peev xwm sib xyaw nrog ib puag ncig yog qhov zoo hauv kev kawm ib puag ncig.
Cov chaw kho mob
Cov tsev kho mob thiab cov chaw kho mob tuaj yeem xa mus rau Ib Phase Pad-Mounted Transformers kom ntseeg tau tias muaj lub zog siv hluav taws xob zoo rau cov khoom siv kho mob, teeb pom kev zoo, thiab lwm yam tseem ceeb. Cov transformers 'compact tsim muaj txiaj ntsig zoo hauv kev noj qab haus huv infrastructure.
Chaw ua si
Chaw ua si, chaw ua si, thiab chaw ua kis las tuaj yeem siv cov kev hloov pauv no rau kev faib hluav taws xob rau cov teeb pom kev zoo, cov chaw cog lus, thiab lwm yam khoom siv. Lub transformers 'kev sib xyaw ua kom zoo nkauj yog tsim rau cov chaw ua si rau pej xeem.
Nyob deb thiab nyob deb nroog
Hauv tej thaj chaw deb lossis nyob deb nroog, Tib Phase Pad -Mounted Transformers tuaj yeem siv los muab hluav taws xob rau cov zej zog nyob ib leeg. Lawv cov qauv tsim tso cai rau kev teeb tsa yooj yim hauv thaj chaw uas qhov chaw txwv tsis pub muaj kev txhawj xeeb tsawg.
Yuav ua li cas rau nruab Ib Phase Pad Mounted Transformer
Kev thauj mus los thiab qhov chaw
Ua tib zoo thauj tib Phase Pad -Mounted Transformer mus rau qhov chaw teeb tsa. Siv cov cuab yeej nqa tsim nyog thiab ua raws li cov txheej txheem kev nyab xeeb thaum thauj. Tso lub transformer ruaj ntseg ntawm lub hauv paus npaj, kom ntseeg tau tias kev sib raug zoo.
Kev sib txuas hluav taws xob
Ua qhov tsim nyog kev sib txuas hluav taws xob raws li lub transformer specifications thiab lub zos hluav taws xob code. Txuas cov thawj thiab theem nrab conductors ruaj ntseg, ua raws li kev rwb thaiv tsev thiab kev txiav tawm kom raug. Yog hais tias lub transformer muaj xws li ib tug kais changer, xyuas kom meej nws zoo kev twb kev txuas.
Hauv av
Tsim kom muaj kev txhim khu kev qha hauv av rau lub transformer. Kev sib txuas hauv av yog qhov tseem ceeb rau kev nyab xeeb thiab kev ua haujlwm ncaj ncees. Ua raws li cov cai hauv av hauv zos thiab xyuas kom meej tias lub tshuab hloov pauv tau zoo sib raug zoo rau hauv av.
Roj filling thiab kuaj
Yog hais tias lub transformer yog roj -immersed, sau lub tank nrog cov ntaub ntawv insulating roj. Ua degassing kom tshem tawm cov huab cua thiab noo noo los ntawm cov roj. Ua cov kev sim thawj zaug, suav nrog kev sim dielectric zog, kom ntseeg tau tias cov roj thiab cov rwb thaiv tsev ua tau raws li cov qauv xav tau.
Kev tiv thaiv thiab kev nyab xeeb nta
Txheeb xyuas qhov ua haujlwm zoo ntawm cov khoom siv tiv thaiv xws li fuses, keyboards, Buchholz relay, thiab lwm yam kev nyab xeeb. Xyuas kom meej tias tag nrho cov cuab yeej tiv thaiv raug ntsuas kom raug thiab teeb tsa kom muaj kev tiv thaiv zoo tiv thaiv kev ua txhaum.

Yuav Ua Li Cas Ib Theem Pad Mounted Transformers pab txhawb rau daim phiaj hluav taws xob
Tib Phase Pad-Mounted Transformers pab txhawb rau cov phiaj xwm hluav taws xob los ntawm kev ua haujlwm tseem ceeb hauv kev faib khoom network. Cov transformers no ua lub luag haujlwm tseem ceeb hauv kev sib kis tau zoo thiab muaj kev nyab xeeb ntawm cov hluav taws xob hluav taws xob los ntawm qib siab voltage mus rau qis voltage, ua rau lawv haum rau ntau yam kev siv. Ib qho txiaj ntsig tseem ceeb yog lawv lub peev xwm los pab txhawb kev faib hluav taws xob faib hluav taws xob, tshwj xeeb hauv cov cheeb tsam uas muaj qhov txwv tsis pub siv lossis kev xav txog kev zoo nkauj. Lub compact tsim thiab sab nraum zoov installation muaj peev xwm ntawm Ib Phase Pad-Mounted Transformers ua rau lawv zoo- haum rau hauv nroog, suburban, thiab thaj chaw nyob.
Cov transformers no txhim khu kev cia siab ntawm daim phiaj los ntawm kev nqis qis qis rau kev faib khoom hauv zos, kom ntseeg tau tias qhov kawg - cov neeg siv tau txais hluav taws xob ntawm cov qib tsim nyog. Lawv txoj kev xa mus rau ntau qhov chaw, suav nrog thaj chaw nyob, thaj chaw lag luam, thiab cov chaw tsim khoom, pab ua kom tau raws li cov kev xav tau ntawm cov zej zog sib txawv. Tsis tas li ntawd, Ib Phase Pad-Mounted Transformers pab txhawb kev nyab xeeb thiab kev tiv thaiv kab mob los ntawm cov yam ntxwv xws li cov cuab yeej tiv thaiv, kev siv hauv av, thiab kev rwb thaiv tsev ruaj khov. Lawv ua lub luag haujlwm hauv kev tiv thaiv thiab txo cov teeb meem hluav taws xob, ua kom muaj kev ruaj ntseg tag nrho ntawm kev faib khoom.
Dab tsi yog Qhov Kev Ua Tau Zoo ntawm Ib Ntu Phaj Pad Mounted Transformer yog dab tsi
Kev ua tau zoo ntawm Ib Phase Pad-Mounted Transformer hais txog nws lub peev xwm los hloov hluav taws xob hluav taws xob nrog tsawg zog poob thaum lub sij hawm hloov hluav taws xob. Feem ntau qhia raws li qhov feem pua, kev ua haujlwm ntawm lub tshuab hluav taws xob tau cuam tshuam los ntawm cov khoom xws li cov ntaub ntawv tseem ceeb thiab cov khoom siv winding, tsim, thauj khoom, thiab cov roj insulating siv.
Niaj hnub Ib Phase Pad-Mounted Transformers yog tsim los nrog kev tsom mus rau kev ua tiav qib siab. Kev siv cov ntaub ntawv qib siab -, xws li cov tub ntxhais laminations zoo thiab cov khoom siv hluav taws xob, ua rau txo qis zog. Tsis tas li ntawd, kev nce qib hauv kev tsim hluav taws xob, suav nrog kev txhim kho cua txias thiab cov txheej txheem rwb thaiv tsev, ntxiv dag zog rau tag nrho kev ua haujlwm. Kev ua tau zoo feem ntau yog qhov siab tshaj plaws thaum lub tshuab hloov pauv ua haujlwm ze nws qhov peev xwm ntsuas. Ntawm cov khoom sib zog, qhov ua tau zoo tuaj yeem txo qis vim qhov kev poob ruaj khov cuam tshuam nrog cov tub ntxhais poob thiab winding tsis kam.

Yuav Ua Li Cas Koj Txias Ib Theem Pad Mounted Transformer
Txias nyob rau hauv Ib Phase Pad-Mounted Transformer yog qhov tseem ceeb rau kev tswj xyuas qhov kub thiab txias thiab ua kom muaj kev ua tau zoo. Muaj ntau txoj hauv kev tau ua haujlwm kom txias cov transformers, nyob ntawm seb lawv tsim thiab siv. Ob txoj hauv kev txias txias yog
Natural convection (tus kheej-txias)
Tib Theem Pad-Mounted Transformers feem ntau tso siab rau ntuj convection kom txias. Lub transformer yog tsim los nrog cov cua txias fins los yog radiators uas ua rau kom thaj chaw saum npoo raug rau cov huab cua ib puag ncig. Raws li lub transformer ua hauj lwm thiab heats li, lub ntuj ncig ntawm huab cua nyob ib ncig ntawm lub qhov chaw txias yuav pab dissipate tshav kub. Txoj kev no siv tau rau cov transformers nrog qis zog ntsuas thiab qhov twg qhov yuav tsum tau ua kom txias tuaj yeem ua tau raws li huab cua ambient.
Forced cua txias
Nyob rau hauv cov xwm txheej uas ntuj convection yuav tsis muab qhov txias txaus, tshwj xeeb tshaj yog rau cov transformers uas muaj zog dua, yuam cua txias yog ua hauj lwm. Qhov no suav nrog kev siv cov kiv cua lossis cov tshuab ua kom nquag plias cua hla lub tshuab cua txias qhov chaw. Cov cua quab yuam ua kom cov cua kub dissipation, cia lub transformer ua hauj lwm ntawm cov loads siab dua yam tsis muaj overheating. Kev quab yuam cua txias yog qhov tshwj xeeb tshaj yog nyob rau hauv ib puag ncig uas muaj qhov kub thiab txias ntau dua los yog qhov yuav tsum tau ua kom txias ntxiv.
Kev xaiv ntawm ntuj convection thiab yuam cua txias yog nyob ntawm cov yam ntxwv xws li transformer lub zog ntsuas, daim ntawv thov, ib puag ncig tej yam kev mob, thiab qhov xav tau qib ntawm kev ua kom txias. Cov neeg tsim khoom ua tib zoo tsim cov tshuab hloov pauv kom ntseeg tau tias txoj kev xaiv txias ua tau raws li cov txheej txheem kev ua tau zoo thiab ua kom muaj kev nyab xeeb ntawm kev ua haujlwm kub.
Nyob rau hauv ob qho tib si txias txoj kev, cov roj insulating nyob rau hauv lub transformer kuj plays lub luag hauj lwm nyob rau hauv dissipating tshav kub. Cov roj absorbs cua sov tsim thaum lub sij hawm ua hauj lwm thiab hloov nws mus rau qhov chaw txias, los ntawm qhov uas nws yog ces dissipated rau hauv ib puag ncig huab cua. Kev saib xyuas tsis tu ncua ntawm lub tshuab hloov hluav taws xob ua haujlwm kub thiab txias txias yog qhov tseem ceeb los xyuas kom meej tias nws nyob hauv qhov txwv tsis pub muaj kev nyab xeeb. Kev ua kom txias kom zoo ua rau lub tshuab hluav taws xob ua haujlwm tau zoo, ua haujlwm ntev, thiab txhim khu kev qha hauv ntau daim ntawv thov hluav taws xob.
Yuav Ua Li Cas Ib Phase Pad Mounted Transformers pab txhawb kev txuag hluav taws xob
Ib Phase Pad-Mounted Transformers pab txhawb kev txuag hluav taws xob los ntawm lawv cov qauv tsim thiab kev ua haujlwm zoo. Cov transformers no ua lub luag haujlwm tseem ceeb hauv cov hluav taws xob faib hluav taws xob, kom ntseeg tau tias lub zog xa mus thiab faib nrog qhov poob tsawg.
High efficiency tsim
Niaj hnub nimno Ib Phase Pad-Mounted Transformers yog tsim los nrog kev tsom mus rau kev ua haujlwm siab, siv cov ntaub ntawv siab heev thiab kev tsim kho kom txo tau lub zog poob thaum lub sijhawm hloov hluav taws xob.
01
Optimized core thiab winding cov ntaub ntawv
Kev siv cov khoom tseem ceeb zoo, xws li laminated silicon steel, thiab cov khoom siv winding, xws li tooj liab lossis txhuas, ua rau txo cov tub ntxhais poob thiab winding tsis kam. Qhov no optimization txhim khu tag nrho cov efficiency ntawm lub transformer.
02
Cov cua txias ua haujlwm zoo
Cov transformers suav nrog cov tshuab ua kom txias, xws li los ntawm ntuj convection lossis yuam cua txias. Kev tswj xyuas qhov kub thiab txias ua haujlwm kom ntseeg tau tias lub zog tsis raug nkim li cov cua sov ntau dhau, ua rau kev txuag hluav taws xob tag nrho.
03
Load efficiency
Tib Phase Pad-Mounted Transformers yog tsim los ua haujlwm zoo nyob rau hauv ib qho kev thauj khoom tshwj xeeb. Los ntawm kev sib piv cov transformer lub peev xwm mus rau qhov tseeb load yuav tsum, lub zog nkim vim underutilization los yog overloading yog tsawg.
04
Kev xav txog ib puag ncig
Kev siv cov roj hluav taws xob zoo ib puag ncig, xws li ntuj esters lossis cov khoom siv hluavtaws, ua raws cov hom phiaj kev txuag hluav taws xob los ntawm kev txo cov kev cuam tshuam ib puag ncig cuam tshuam nrog kev ua haujlwm transformer. Cov roj no muaj kev rwb thaiv tsev zoo thiab cua txias thaum ua kom ruaj khov dua.
05
Kev daws teeb meem ntawm Ib Phase Pad -Mounted Transformer koom nrog txoj hauv kev los txheeb xyuas thiab daws cov teeb meem uas cuam tshuam rau nws qhov kev ua tau zoo. Nov yog cov kauj ruam tseem ceeb hauv kev daws teeb meem
Kev tshuaj xyuas qhov muag
Pib nrog kev tshuaj xyuas kom pom tseeb ntawm lub tshuab hloov pauv, tshuaj xyuas cov cim qhia ntawm lub cev puas tsuaj, cov roj xau, lossis kev sib txuas xoob. Xyuas kom meej tias lub transformer ib puag ncig yog qhov tseeb thiab tsis muaj kev cuam tshuam.
Kev ntsuas kub
Saib xyuas qhov kev khiav hauj lwm kub ntawm lub transformer. Kev hloov pauv ntawm qhov kub tsis zoo yuav qhia tau tias muaj teeb meem nrog kev ua kom txias lossis overloading. Infrared thermography tuaj yeem siv los txheeb xyuas cov hotspots.
Roj tsom xam
Ua cov roj tshuaj ntsuam xyuas qhov xwm txheej ntawm cov roj insulating. Kev nce qib ntawm cov dej noo, cov khoom paug, lossis kev degradation los ntawm - cov khoom yuav qhia tau tias muaj teeb meem. Ua cov kev ntsuam xyuas xws li kev txheeb xyuas cov roj yaj rau kev tshawb pom ntxov ntawm qhov tsis raug sab hauv.
Kev kuaj hluav taws xob
Ua kev ntsuam xyuas hluav taws xob, suav nrog kev ntsuas kev tiv thaiv hluav taws xob thiab kev ntsuas lub zog dielectric, txhawm rau ntsuas kev ncaj ncees ntawm cov hluav taws xob rwb thaiv tsev. Tshawb xyuas qhov txawv txav ntawm qhov kev nyeem ntawv voltage, thiab xyuas kom meej tias cov thawj thiab theem nrab voltages nyob rau hauv cov kev txwv.
Xyuas cov cuab yeej tiv thaiv
Txheeb xyuas qhov ua haujlwm zoo ntawm cov khoom siv tiv thaiv, xws li fuses thiab relays. Xyuas kom meej tias cov cuab yeej no raug ntsuas kom tsim nyog thiab teeb tsa los teb rau cov xwm txheej txawv txav, muab kev tiv thaiv zoo tiv thaiv kev ua txhaum.
Coj mus rhaub changer tshuaj ntsuam
Yog hais tias lub transformer muaj ib tug kais changer, xyuas nws cov hauj lwm. Tshawb xyuas txhua qhov teeb meem hauv kev hloov pauv qhov sib piv thiab xyuas kom meej tias cov kais hloov pauv cov neeg sib cuag tau zoo.
Grounding system check
Xyuas kom meej tias lub transformer lub hauv paus system yog zoo thiab siv tau. Kev sib txuas hauv av txhim khu kev qha yog qhov tseem ceeb rau kev nyab xeeb thiab kev ua haujlwm kom raug.
Tib Phase Pad-Mounted Transformers yog tsim los tswj cov kev siv hluav taws xob siab nrog kev ua haujlwm thiab kev ntseeg siab. Ntawm no yog cov kev xav tseem ceeb ntawm yuav ua li cas cov transformers tswj cov hluav taws xob siab
Kev hloov hluav taws xob
Tib Phase Pad-Mounted Transformers feem ntau yog lub luag haujlwm rau kev hloov pauv cov hluav taws xob siab tshaj plaws kom qis dua theem nrab voltages haum rau kev faib khoom. Qhov kev hloov hluav taws xob no tau ua tiav los ntawm kev sib cuam tshuam ntawm thawj thiab theem nrab windings, ua raws li cov hauv paus ntsiab lus ntawm electromagnetic induction.
Rwb thaiv tsev systems
Cov ntawv thov hluav taws xob siab xav tau cov tshuab hluav taws xob muaj zog los tiv thaiv hluav taws xob tawg thiab ua kom muaj kev nyab xeeb thiab kev ncaj ncees ntawm lub transformer. Tib Theem Pad-Mounted Transformers suav nrog cov khoom siv hluav taws xob zoo, xws li roj- cov ntawv impregnated lossis cov khoom siv hluav taws xob hluavtaws, los muab cov khoom siv hluav taws xob zoo.
Dielectric zog
Cov roj insulating nyob rau hauv lub transformer plays lub luag haujlwm tseem ceeb hauv kev tswj lub zog dielectric. Cov roj raug xaiv thiab ua tiav kom tiv taus hluav taws xob siab thiab muab cov rwb thaiv tsev zoo, ua kom lub tshuab hluav taws xob muaj peev xwm tswj tau qhov hluav taws xob siab tsis muaj kev puas tsuaj.
Core thiab winding tsim
Kev tsim ntawm lub transformer lub hauv paus thiab windings yog ib qho tseem ceeb rau kev tswj cov high voltages. Cov ntaub ntawv zoo, xws li laminated silicon steel rau cov tub ntxhais thiab cov khoom siv hluav taws xob xws li tooj liab lossis txhuas rau cov windings, pab txo qis kev poob thiab txhim kho lub transformer lub peev xwm los tswj cov qib high voltage.
BIL ( theem pib impulse) rating
Ib Phase Pad-Mounted Transformers tau muab qhov ntsuas qhov ntsuas qhov yooj yim Impulse (BIL), qhia lawv lub peev xwm los tiv thaiv xob laim thiab cov hluav taws xob dhau mus. Kev ntsuas BIL ua kom ntseeg tau tias lub tshuab hloov pauv tuaj yeem tiv taus siab -voltage surges yam tsis muaj kev cuam tshuam nws cov rwb thaiv tsev.
Kev tswj hluav taws xob
Cov transformers no yog tsim los muab kev ruaj khov thiab tswj cov theem nrab voltages txawm tias muaj kev hloov pauv hauv cov khoom siv hluav taws xob. Cov txheej txheem tswj hluav taws xob, suav nrog cov kais hloov pauv, pab tswj kom muaj qhov tso tawm hluav taws xob zoo ib yam nyob rau hauv qhov sib txawv ntawm kev thauj khoom thiab cov khoom nkag.
Surge arresters
Hauv kev siv hluav taws xob siab, surge arresters yuav raug ntsia los tiv thaiv lub transformer los ntawm overvoltage tej yam kev mob tshwm sim los ntawm xob laim lossis hloov cov xwm txheej. Surge arresters divert tshaj voltage rau hauv av, tiv thaiv kev puas tsuaj rau lub transformer.
Yuav Ua Li Cas Tswj Ib Theem Pad Mounted Transformer
Kev kuaj pom tsis tu ncua
Ua qhov kev tshuaj xyuas tsis tu ncua txhawm rau txheeb xyuas cov cim qhia ntawm lub cev puas tsuaj, cov roj xau, lossis kev sib txuas xoob. Tshawb xyuas lub transformer ib puag ncig kom ntseeg tau tias qhov cua kom zoo thiab kev nkag tau meej.
Kev ntsuas kub
Saib xyuas qhov kev khiav hauj lwm kub ntawm lub transformer. Kev hloov pauv ntawm qhov kub tsis zoo yuav qhia tau tias muaj teeb meem nrog kev ua kom txias lossis overloading. Periodic infrared thermography tuaj yeem siv los txheeb xyuas cov hotspots.
Roj sampling thiab tsom xam
Ua cov roj sampling niaj hnub thiab tsom xam los ntsuas qhov xwm txheej ntawm cov roj insulating. Kev txheeb xyuas cov roj tuaj yeem muab kev nkag siab txog cov teeb meem muaj peev xwm xws li cov dej noo, kev sib kis, lossis kev puas tsuaj.
Ua raws li cov chaw tsim khoom pom zoo rau lub sijhawm kuaj roj.
Kev kuaj hluav taws xob
Ua cov kev ntsuam xyuas hluav taws xob raws sij hawm, suav nrog kev ntsuas kev tiv thaiv hluav taws xob thiab kev ntsuas lub zog dielectric, txhawm rau ntsuas qhov ncaj ncees ntawm cov rwb thaiv tsev. Xyuas kom tseeb tias cov thawj thiab theem nrab voltages nyob rau hauv cov kev txwv. Tsis tu ncua xyuas kev ua haujlwm ntawm cov cuab yeej tiv thaiv.
Coj mus rhaub changer tu
Yog tias lub tshuab hloov pauv tau nruab nrog lub tshuab hloov pauv, tshuaj xyuas thiab tswj nws cov haujlwm. Xyuas kom meej tias cov kais hloov pauv cov neeg nyob hauv qhov zoo thiab tias lub tshuab ua haujlwm zoo.
Grounding system check
Lub sij hawm xyuas lub transformer lub hauv paus system kom paub meej nws cov hauj lwm zoo. Kev sib txuas hauv av txhim khu kev qha yog qhov tseem ceeb rau kev nyab xeeb thiab kev ua haujlwm kom raug.
Kev huv huv
Khaws lub transformer thiab nws ib puag ncig kom huv si. Tshem tawm cov av, khib nyiab, thiab cov nroj tsuag uas tuaj yeem cuam tshuam qhov cua. Xyuas kom meej tias cov fins txias los yog radiators tsis muaj kev cuam tshuam.
yees duab
Cov ntawv pov thawj


Peb lub Hoobkas
Jiangsu Yawei Transformer Co., Ltd. yog nyob rau hauv Hai'an City, Jiangsu Province, Suav. Peb yog cov kws tshaj lij kev tsim hluav taws xob hloov hluav taws xob thiab cov khoom siv hluav taws xob siab -voltage hluav taws xob, tshwj xeeb tshaj yog tsom rau lub zog hluav taws xob, suav nrog cov chaw nres tsheb, cov tshuab xa hluav taws xob, thiab cov kab sib kis. Peb lub lag luam thoob ntiaj teb ua rau peb nyob ntawm qhov ua ntej ntawm cov neeg siv khoom xav tau thiab kev daws teeb meem. Los ntawm xyoo dhau los ntawm kev tsim hluav taws xob thoob ntiaj teb, peb lub Hoobkas muaj peev xwm tsim cov khoom siv hluav taws xob uas ua tau raws li cov qauv thoob ntiaj teb xws li IEC, IEEE, ANSI, CSA, EN, thiab lwm yam.




FAQ
Cim npe nrov: Tuam Tshoj ib theem pad mounted transformer manufacturers, lwm tus neeg, Hoobkas







