Koj puas paub qhov zoo ntawm Isolating Transformers?

Muab cais nyob ib leegtransformeryog ib hom transformer nrog cua ua qhov nruab nrab cua txias. Ib tug transformer nrog hluav taws xob cais ntawm cov input winding thiab cov zis winding. Kev rho tawm transformer yog siv los tiv thaiv kev sib chwv lub cev nyob rau tib lub sijhawm. Kev rho tawm transformer yog siv los cais cov tam sim no ntawm thawj theem nrab winding coil. Cov khoom xa tuaj, tseem hu ua commutator reactor, tuaj yeem txwv qhov kev poob siab tam sim no los ntawm kev hloov pauv hluav taws xob thiab kev ua haujlwm dhau ntawm lub zog hluav taws xob, tiv thaiv cov khoom siv hluav taws xob zoo, thiab tiv thaiv xov tooj cua cuam tshuam, thiab tiv thaiv thiab txhim kho nws lub zog. Peb-theem reactor yog siv nyob rau hauv series nrog lub inlet thiab qhov hluav taws xob terminals ntawm lub zaus converter, raws li lub inlet thiab qhov hluav taws xob reactors ntawm lub zaus converter, uas yuav txo tau cov harmonics generated thaum lub zaus converter ua hauj lwm. Sib txawv ntawm cov roj-immersed transformers, nws tsuas yog siv cov cua txias thiab yuam cua txias. Cov huab cua txias ntuj yog siv rau cov transformers uas muaj peev xwm me me thiab kev ua haujlwm ntev, thiab cua txias txias yog siv rau cov transformers uas muaj peev xwm loj thiab kub siab. Tsis tas li ntawd, qhov tsim nyog qhov ntsuas kub tau tso cai rau hauv kev ua haujlwm, uas yog qhov tseem ceeb los txhim kho kev nyab xeeb thiab kev ruaj ntseg ntawm kev siv transformer hauv cov tshuab hluav taws xob. Niaj hnub no, peb yuav tham txog qhov zoo ntawm kev rho tawm transformers. Cia peb saib.

(1) Kev rho tawm hluav taws xob thev naus laus zis tuaj yeem zam qhov kev pheej hmoo ntawm hluav taws kub thiab tawg ntawm cov roj transformer vim tsis ua haujlwm hauv kev lag luam. Vim hais tias cov ntaub ntawv insulating ntawm kev sib cais transformer yog cov khoom siv refractory, txawm tias qee qhov kev ua tsis tiav ntawm lub transformer hauv kev ua haujlwm ntawm qhov system ua rau hluav taws kub los yog lwm qhov hluav taws kub, nws yuav tsis ua rau qhov hluav taws kub txuas ntxiv.

2. Lub tshuab hluav taws xob sib cais tsis muaj qhov teeb meem ntawm cov roj xau tib yam li cov roj-immersed transformer, thiab tsis muaj teeb meem ntawm kev laus transformer roj.

3, kev rho tawm transformer feem ntau yog cov khoom siv hauv tsev, rau qhov tshwj xeeb ntawm qhov chaw tuaj yeem ua rau sab nraum zoov, nws tuaj yeem ntsia tau rau hauv tib chav nrog lub txee hloov, txo qhov chaw teeb tsa.

4. Vim tias qhov kev hloov pauv hloov pauv tsis muaj roj, muaj cov khoom siv tsawg dua, tsis muaj roj cia tank, tsis muaj kev nyab xeeb ntawm cov pa, li qub thiab lwm yam, thiab tsis muaj teeb meem kev sib khi.

5, kev sib cais thiab kev hloov hluav taws xob rwb thaiv tsev thev naus laus zis ua tau zoo, muaj kev ntseeg tau zoo. Qhov tso cai kub nce ntawm kev sib cais ua haujlwm transformer, piv nrog cov tsoos roj-immersed transformer, tau zoo heev txhim kho cov dej-pov thawj system ua haujlwm ntawm kev sib cais transformer.

6. Kev rho tawm transformer yog ntau thiab ntau siv nyob rau hauv ntau lub zog tej yaam num vim hais tias ntawm nws zoo kev nyab xeeb kev ua tau zoo, tsis tshua muaj zog noj, noo-pov thawj, yooj yim ua hauj lwm thiab yooj yim txij nkawm.

Cov no yog rau qhov zoo ntawm kev rho tawm transformers. Nws tuaj yeem tsis tsuas yog zam qhov kev phom sij ntawm cov roj hluav taws xob hluav taws xob thiab tawg los ntawm kev ua haujlwm tsis raug, tab sis kuj muaj kev ua haujlwm zoo rwb thaiv tsev, muaj kev ntseeg tau zoo, kev nyab xeeb zoo, kev siv hluav taws xob tsawg, tsis muaj dej tsis zoo, kev ua haujlwm yooj yim thiab kev saib xyuas yooj yim. Siv dav hauv cov tsev hauv nroog, cov chaw tsheb ciav hlau thauj mus los thiab lwm qhov chaw pej xeem.

news-800-558

Xa kev nug