cov khoom piav qhia
220 Polyamide-lmide Enameled Copper Rectangle Wire nws muaj cua sov ua haujlwm, tub yees tsis kam, txias txias tsis kam, hluav taws xob tiv thaiv, thiab lwm yam., siab mechanical zog, ruaj khov huab cua ua haujlwm, zoo tshuaj tiv thaiv thiab refrigerant, thiab muaj zog tshaj lub peev xwm. Nws yog dav siv nyob rau hauv tub yees compressors, cua txias compressors, hluav taws xob cov cuab yeej, tawg-pov thawj motors, thiab motors thiab hluav taws xob khoom siv nyob rau hauv kub kub, txias, hluav taws xob tiv thaiv, overload thiab lwm yam kev mob. Cov khoom tsim los ntawm nws muaj cov yam ntxwv ntawm qhov me me, kev ua haujlwm ruaj khov, kev ua haujlwm zoo thiab kev txuag hluav taws xob tseem ceeb.
Vim li cas Ib Tug Neeg Yuav Xav Siv Cov Hlau Rectangle Hloov Cov Hlau Round Round?
Kev siv cov square-shaped hlau, tseem hu ua cov hlau plaub, es tsis yog ib txwm puag ncig hlau, tuaj yeem nthuav qhia ntau yam zoo nyob ntawm daim ntawv thov tshwj xeeb. Nov yog qee qhov laj thawj vim li cas square-shaped hlau yuav nyiam:
Nce ntim ceev:Square hlau ua pov thawj zoo nyob rau hauv cov xwm txheej uas qhov chaw txwv. Thaum coiled, qhov sib npaug ntawm cov xaim square tuaj yeem raug teeb tsa hauv qhov kev teeb tsa denser piv rau cov hlau puag ncig. Cov cwj pwm no muaj txiaj ntsig tshwj xeeb hauv cov ntawv thov nrog qhov chaw txwv lossis qhov uas ua kom muaj pes tsawg tus neeg xyuas yog qhov tseem ceeb.
Enhanced Thaum tshav kub kub Dissipation:Square xaim, nrog nws thaj chaw loj dua, pab txhim kho cov cua sov kom zoo, ua rau nws tsim nyog rau cov ntawv thov tsim cov cua sov tseem ceeb. Qhov no feature pab tiv thaiv overheating thiab txhim khu tag nrho cov thermal kev ua tau zoo ntawm lub system.
Txo cov tawv nqaij zoo:Square hlau mitigates cov nyhuv ntawm daim tawv nqaij, qhov twg high-frequency tam sim no yuav mloog zoo nyob ze ntawm tus neeg xyuas pib. Qhov nce saum npoo ntawm cov xaim square tso cai rau kev faib tawm ntau dua ntawm tam sim no piv rau cov xaim puag ncig.
Txhim kho Mechanical Stability:Square xaim muaj kev txhim kho kev ruaj ntseg thiab txo qis zog piv rau cov hlau puag ncig. Nws cov duab square muab cov ntsiab lus sib txuas ntxiv ntawm cov xov hlau uas nyob ib sab, txo qis qhov tshwm sim ntawm cov xaim txav los yog hloov mus rau hauv ib qho winding. Cov cuab yeej no txhim kho cov neeg kho tshuab kev ncaj ncees thiab kev ntseeg siab ntawm lub kaw lus, tshwj xeeb tshaj yog nyob rau hauv cov ntawv thov raug kev co los yog kev siv tshuab.
Enhanced Coil Shape Control:Square hlau ua kom muaj kev tswj xyuas zoo dua ntawm cov duab thiab qhov ntev ntawm cov coils lossis windings. Lub kaum sab xis ntawm cov hlau square pab kom meej qhov chaw thiab kev sib haum xeeb thaum lub sij hawm winding txheej txheem, ua rau cov coils nrog zoo ib yam thiab qhov ntev.
Nta ntawm Enameled Copper Hlau
Tsawg Resistivity:Qhov hluav taws xob tsis kam ntawm enamel tooj liab cable yog li 1.68 npaug siab dua li ntawm cov tooj liab hlau cable. nyem qhov no kom paub meej ntxiv.
Ductility zoo:Lub elongation tus nqi ntawm tooj liab alloy yog 20 ~ 40%, qhov elongation tus nqi ntawm tooj liab rau cov hluav taws xob yog siab dua 30%, thiab aluminium alloy tsuas yog 18%.
Siab zog:Tso cai rau kev ntxhov siab ntawm qhov kub thiab txias, tooj liab yog 7 ~ 28% siab dua txhuas. Tshwj xeeb tshaj yog qhov kev ntxhov siab ntawm qhov kub thiab txias, qhov sib txawv ntawm ob yog nyob deb.
Anti-Fatigue:Aluminium yog yooj yim khoov thiab tawg, thiab tooj liab tsis yooj yim. Nyob rau hauv cov nqe lus ntawm elasticity, tooj liab kuj yog hais txog 1.7 mus rau 1.8 lub sij hawm siab tshaj txhuas.
Zoo Stability, Corrosion Resistance:Tooj hlau yog resistant rau oxidation thiab corrosion, thiab txhuas hlau yog raug rau oxidation thiab corrosion.
High Current Carrying Peev Xwm:Ua tsaug rau nws qhov kev tiv thaiv qis, enameled tooj liab hlau cable ntawm tib qhov chaw hla ntu tuaj yeem haum 30% -50% tam sim no ntau dua li qhov tso cai muaj peev xwm ntawm txhuas hlau cable, tshwj xeeb tshaj yog cov khoom siv hauv tsev siv tooj liab hauv kev tsim vaj tsev. .
Tsawg Voltage Loss:Nrog nws cov tsis tshua muaj kev tiv thaiv, tooj liab hlau cable muaj qhov tsawg kawg nkaus qhov hluav taws xob poob rau tib qhov tam sim no ntws hauv qhov sib npaug. Yog li ntawd, nws ua kom zoo dua qhov hluav taws xob zoo tshaj tib qhov kev sib kis. Xwb, nyob rau hauv qhov tso cai voltage poob txwv, tooj liab cable ua rau kev xa hluav taws xob mus ntev, nthuav cov cheeb tsam kev pab cuam thiab ua kom cov phiaj xwm sib txuas los ntawm kev txo cov naj npawb ntawm cov ntsiab lus fais fab.
Txo Thaum tshav kub kub Generation:Piv nrog rau aluminium hlau cable, tooj liab hlau ntawm qhov sib npaug ntawm qhov sib npaug ntawm qhov sib npaug ua kom muaj cua sov tsawg dua nyob rau hauv cov khoom siv tam sim no zoo ib yam, txhim kho kev nyab xeeb ntawm kev ua haujlwm.

Cov txheej txheem ntau lawm ntawm Enamel Coated Hlau
Them tawm
Them tawm yog hais txog cov txheej txheem ntawm unwinding hlau ntawm tus qauv enamelling tshuab. Txhawm rau txo tus neeg teb xov tooj lub zog thiab lub cev poob, ib qho kev coj ua yog siv txoj kev them nyiaj loj-muaj peev xwm. Qhov tseem ceeb ntawm kev them nyiaj yog kom muaj kev sib haum xeeb thiab tsim nyog. Cov xov hlau sib txawv yuav tsum muaj qhov sib txawv ntawm kev them nyiaj: qhov loj-loj thiab loj-muaj peev xwm spools feem ntau ntiav radial rotary them-offs, thaum nruab nrab-loj xov hlau feem ntau siv dhau-kawg lossis txhuam-hom them nyiaj.
Annealing
Annealing tshwm sim tom qab xaim tawm. Nws lub hom phiaj yog txhawm rau cuam tshuam cov qauv molecular lattice, tso cai rau cov hlau kom rov ua tau qhov muag muag tom qab tau rhuab mus rau qhov kub thiab txias thaum lub sij hawm tso tawm. Nyob rau tib lub sijhawm, annealing tshem tawm cov roj nplua nyeem lossis cov roj stains uas tau sau thaum lub sijhawm ncab, ua kom cov enamel coated hlau zoo. Tom qab annealing, cov txheej txheem painting pib, nyob rau hauv cov xim yog siv rau cov hlau conductor los tsim ib tug uniform xim txheej ntawm lub thickness. Txawv hlau specifications thiab painting txoj kev dictate sib txawv viscosity yuav tsum tau rau cov xim.
Painting thiab ci
Tom qab annealing, txheej txheem tha xim ensues, tsom rau kev thov cov xim rau cov hlau conductor los ua ib txheej txheej ntawm cov thickness. Viscosity yuav tsum tau rau cov xim txawv nyob ntawm seb cov hlau specifications thiab painting txoj kev. Feem ntau, enamel coated tooj liab hlau hla ntau txheej thiab ci cycles los pab ua kom tiav cov kuab tshuaj evaporation thiab resin cov tshuaj tiv thaiv, ua rau cov xim pleev xim rau cov yeeb yaj kiab. Baking, akin rau painting, yog ib tug cyclical txheej txheem uas muaj cov kuab tshuaj evaporation, kho los ua ib tug xim zaj duab xis, thiab tom qab painting thiab ci cycles.
Cua txias thiab cua txias
Enamel coated hlau tawm hauv qhov cub yog qhov kub thiab txias, nrog cov xim mos thiab tsis muaj zog. Tsis ua kom txias tam sim tuaj yeem ua rau cov xim zaj duab xis puas thaum dhau los ntawm kev qhia lub log, yog li cuam tshuam cov hlau zoo. Txias yog ua raws li cov xaim nqa, tsom rau winding lub enamel coated hlau tsis tu ncua, nruj nreem, thiab sib npaug mus rau bobbin. Lub tshuab nqa xaim yuav tsum muaj kev sib kis tau ruaj khov, tawm suab nrov, tswj kom nruj, thiab xyuas kom muaj kev sib txuas zoo.
peb lub Hoobkas





FAQs ntawm Polyamide-Lmide Enameled Copper (Aluminium) Rectangle Hlau
Q: Dab tsi yog qhov txawv ntawm tooj liab hlau thiab enameled tooj liab hlau?
Q: Dab tsi yog enameled aluminium hlau?
Q: Dab tsi yog qhov zoo ntawm enamel coated tooj liab hlau?
Q: Dab tsi yog qhov txawv ntawm liab qab hlau thiab enameled hlau?
Q: Vim li cas siv enameled hlau?
Q: Cov hlau twg zoo dua Aluminium lossis tooj liab?
Q: Kuv yuav ua li cas thiaj paub yog tias kuv cov hlau yog enameled?
Q: Dab tsi yog tooj liab coated txhuas hlau siv rau?
Q: Dab tsi yog enameled tooj liab hlau siv rau?
Q: Puas yog enameled tooj liab hlau conductive?
Cim npe nrov: 220 polyamide-lmide enameled tooj liab (aluminium) duab plaub hlau, Tuam Tshoj 220 polyamide-lmide enameled tooj liab (aluminium) duab plaub hlau manufacturers, lwm tus neeg, Hoobkas





