admin@yaweitransformer.cn    +86-18651392209
Cont

Puas muaj lus nug?

+86-18651392209

Daim Ntawv Pov Thawj Copper Rectangle Hlau

Daim Ntawv Pov Thawj Copper Rectangle Hlau

Cov qauv khoom: ZB(L)-0 30-1.25 mm;
Thickness loj {{0}}a: 0.80-5.60mm;
Dav loj ---b: 2.00~ 16.{4}}mm.
Cov qauv kev coj ua: GB / T 7673.3-2008 / IEC 60317-27: 1998.
Xa kev nug

Khoom Taw qhia

vim li cas xaiv peb
 
 
 

Pab neeg tshaj lij

Peb cov kws tshaj lij pab pawg sib koom tes thiab sib txuas lus zoo nrog ib leeg, thiab tau cog lus los muab cov txiaj ntsig zoo. Lawv muaj peev xwm los daws cov teeb meem nyuaj thiab cov haujlwm uas xav tau lawv cov kws tshaj lij thiab kev paub dhau los.

 
 

Kev tsim kho tshiab

Peb mob siab rau kev txhim kho peb cov tshuab tsis tu ncua, kom ntseeg tau tias cov cuab yeej peb muab yog ib txwm txiav.

 
 

One Stop Solution

Peb tuaj yeem muab ntau yam kev pabcuam, los ntawm kev sib tham thiab tswv yim rau kev tsim khoom thiab xa khoom. Nws yog qhov yooj yim rau cov neeg siv khoom, raws li lawv tuaj yeem tau txais txhua qhov kev pab lawv xav tau hauv ib qho chaw.

 
 

24h Online Service

Peb sim thiab teb rau txhua qhov kev txhawj xeeb hauv 24 teev thiab peb pab pawg yeej ib txwm muab koj pov tseg thaum muaj xwm txheej ceev.

 

 

cov khoom piav qhia

 

Daim ntawv qhwv tooj liab kab hlau yog ib qho winding ua los ntawm cov hlau tsis muaj oxygen (extruded, kos) los yog hluav taws xob puag ncig aluminium rods extruded los ntawm cov specification tuag thiab ces qhwv nrog insulating ntawv. Daim ntawv npog hlau feem ntau yog siv los ua cov xaim winding ntawm roj-immersed transformers.

 

Cov khoom siv rwb thaiv tsev

 

Cov ntaub ntawv qhwv: Fais fab cable ntawv, high-density insulating ntawv, tshav kub-resistant insulating ntawv, micro-wrinkled ntawv, aromatic polyamide ntawv (NOMEX410 ntawv) thiab ntau yam ntaub ntawv nws tus kheej nplaum, PET zaj duab xis, Finnish ntawv, imported micro-wrinkled insulating ntawv (dennis Pine ntawv), lwm yam ntaub ntawv tshwj xeeb insulating.

 

Khoom siv rau Enameled Hlau: High-strength acetal varnish, polyesterimide, polyesterimide / polyamideimide kua roj vanish, nws tus kheej-nplaum kua roj vanish.

 

Rwb thaiv tsev Thickness thiab tus naj npawb ntawm cov txheej: Txhua lub thickness thiab tus naj npawb ntawm cov khaubncaws sab nraud povtseg tuaj yeem ntim tau. Tus neeg siv tuaj yeem qhia lub hom, qauv thiab specification ntawm cov khoom siv insulating.

 

Daim Ntawv Npog Hlau Ntau Lawm Cov Qauv: IEC, NEMA, GB, JIS

 

Qhov zoo ntawm Daim Ntawv Pov Hwm Copper Rectangle Hlau

 

1. Daim ntawv npog tooj liab tuaj yeem txo tus nqi, txo qhov loj meand Nyhav

Kev siv daim ntawv npog tooj liab hlau hauv insulated qhuav-hom transformers ua rau txo cov nqi tsim kho vim qhov tsawg kawg nkaus ntawm cov xov hlau thiab hlau cores. Qhov tsis muaj vaults thiab roj sums ntxiv ua rau qhov loj thiab qhov hnyav txo, ua kom yooj yim installation. Tsis tas li ntawd, cov tub ntxhais hlau me me txo qhov tsis muaj qhov poob, txhim kho kev ua haujlwm.

 

2. Daim ntawv npog tooj liab tuaj yeem nce ntxivtnws Spare Capacity

Kev sib xyaw ua ke ntawm cov ntawv npog tooj liab hauv cov khoom siv hluav taws xob nrog cov rwb thaiv tsev tso cai rau qhov muaj peev xwm ntau ntxiv los tswj cov xwm txheej thaum muaj xwm txheej ceev thiab kev nthuav dav uas tsis xav txog, yog li txhim kho kev npaj muaj xwm txheej ceev.

 

3. Daim ntawv npog tooj liab tuaj yeem txhim kho kev ntseeg tau

Kev siv cov ntawv-coated electromagnetic wires ua kom muaj hluav taws xob thiab kev ua haujlwm zoo thoob plaws hauv lub neej ntawm transformer. Cov xov hlau no nthuav tawm zoo kawg li tiv thaiv kev laus, shrinkage, thiab deformation, tswj kev ruaj ntseg txawm tias nyob rau hauv luv luv-circuit cuam tshuam tom qab siv ntev, yog li elevating kev cia siab.

Paper Covered Copper Rectangle Wire

Kev siv cov ntawv npog hlau

 

Transformers thiab Coils:Daim ntawv npog cov xov hlau pom muaj ntau daim ntawv thov hauv kev tsim cov transformers thiab coils, qhov chaw uas lawv raug mob nyob ib ncig ntawm lub magnetic core los tsim coils uas pab txhawb voltage thiab tam sim no hloov dua siab tshiab. Cov ntawv rwb thaiv tsev ua haujlwm rau insulate lub kauj los ntawm cov tub ntxhais, yog li tiv thaiv hluav taws xob arcing thiab txhim kho kev ua haujlwm ntawm transformer.

 

Hluav taws xob cov Motors:Daim ntawv npog cov xov hlau yog siv rau hauv kev tsim kho cov tshuab hluav taws xob, qhov chaw uas lawv raug mob nyob ib ncig ntawm lub stator los muab kev tiv thaiv rwb thaiv tsev, txo qhov kev pheej hmoo ntawm hluav taws xob luv luv thiab lwm yam teeb meem.

 

Hluav taws xob Generators:Zoo ib yam li cov tshuab hluav taws xob, cov ntawv npog cov xov hlau yog ua haujlwm hauv kev sib dhos ntawm cov tshuab hluav taws xob. Lawv raug mob nyob ib ncig ntawm ob lub rotor thiab stator, furnishing rwb thaiv tsev thiab pab txhawb rau generator efficiency.

 

Audio Cables:Daim ntawv npog cov xov hlau yog ib qho tseem ceeb rau kev tsim cov suab cables, muab cov rwb thaiv tsev zoo tshaj plaws uas txo qis kev cuam tshuam thiab txhim kho suab zoo. Daim ntawv rwb thaiv tsev kuj imparts durability, tiv thaiv lub cable los ntawm nkig thiab tawg thaum lub sij hawm.

 

Teeb pom kev zoo:Daim ntawv npog xov hlau yog siv rau hauv kev tsim kho cov teeb pom kev zoo los tsim kev sib txuas ntawm lub teeb thiab cov khoom siv hluav taws xob. Qhov no muab kev sib txuas ua kom muaj zog thiab hloov tau yooj yim uas muaj peev xwm tiv taus qhov kub thiab txias thiab kev vibrations cuam tshuam nrog kev siv teeb pom kev zoo.

 

Automotive Kev Lag Luam:Daim ntawv npog cov xov hlau pom daim ntawv thov hauv kev lag luam tsheb, uas lawv tau ua haujlwm los txuas lub roj teeb, lub tshuab hluav taws xob, thiab lwm yam khoom siv hluav taws xob hauv tsheb. Daim ntawv rwb thaiv tsev tiv thaiv cov xov hlau los ntawm cov xwm txheej hnyav ntawm lub cav lub cav, txo kev puas tsuaj thiab txo qhov kev pheej hmoo ntawm hluav taws xob luv.

 

Kev ua haujlwm tshwj xeeb ntawm daim ntawv npog hlau

 

  1. Thaum siv cov rwb thaiv tsev, qhwv nws nruj nreem, sib npaug, thiab du ib ncig ntawm cov hlau. Ib qho kev tsis sib xws hauv zos vim yog cov hlau txuas lossis cov pob qij txha hauv cov ntawv txheej yuav tsum tsis pub tshaj qhov siab tshaj qhov tso cai, uas yog txiav txim siab los ntawm kev ntxiv qhov liab qab hlau qhov ntev, qhov sib txawv, thiab rwb thaiv tsev thickness nrog rau lawv qhov sib txawv.
  2. Daim ntawv thov ntawm insulating daim kab xev los yog ntawv yuav tsum tas mus li, kom ntseeg tau tias tsis muaj qhov khoob lossis kev puas tsuaj raws qhov ntev.
  3. Cov khaubncaws sab nraud povtseg ntawm daim kab xev yuav tsum ua kom siab nyob rau hauv thaj tsam ntawm 2 hli mus rau 1/3 ntawm daim ntawv bandwidth, thaum cov khaubncaws sab nraud povtseg yuav tsum tau siv lub siab ntawm 0.5, nrog rau cov nyiaj tso cai rau docking los xyuas kom meej seam thickness seem. hauv qab 0.5 hli.
  4. Rau cov conductors nrog kev rwb thaiv tsev, nws yog ib qho tseem ceeb kom ntseeg tau tias daim kab xev tsis tawg, thiab thaum cov hlau yog khoov, kev sib txuas ntawm lub taub hau ntawm txheej txheej yuav tsum nyob twj ywm seamless.

 

Kev sib piv ntawm Cov Ntawv-Cov Hlau thiab Enameled Hlau

 

Enameled hlau thiab daim ntawv npog hlau yog qhov kev xaiv dav dav rau cov xov hlau winding. Txawm hais tias lawv siv dav, muaj qhov sib txawv tseem ceeb ntawm ob.

 

Insulating txheej:

Qhov tseem ceeb tsis sib xws yog nyob rau hauv lawv cov txheej insulating. Daim ntawv npog xaim siv cov ntawv insulating, qhov enameled hlau siv cov kua roj vanish, pom tseeb los ntawm lawv cov npe. Qhov sib txawv ntawm cov khoom siv insulating no kuj cuam tshuam rau lawv qhov kev ua tau zoo.

 

Kev ua tau zoo:

Nyob rau hauv cov nqe lus ntawm kev ua tau zoo, daim ntawv-them xaim lags qab enameled hlau nyob rau hauv dej tsis kam thiab kub tsis kam vim nws cov ntaub ntawv insulating muaj pes tsawg leeg. Txawm li cas los xij, daim ntawv npog hlau boasts tus nqi qis dua thiab lub neej ua haujlwm ntev, yog li tag nrho cov nqi ua haujlwm kuj zoo heev.

 

Daim ntawv thov:

Ob hom pom kev siv hauv cov khoom siv hluav taws xob xws li transformers. Txawm li cas los xij, enameled hlau nyiam ntau yam kev siv. Xaiv qhov tsim nyog winding hlau raws li ib puag ncig kev siv tshwj xeeb ua kom pom kev ua haujlwm zoo thiab raug nqi.

 

FAQs

Q: Cov khoom siv dab tsi yog siv los npog tooj liab?

A: Feem ntau, hlau rwb thaiv tsev yog ua los ntawm ntau hom yas los yog polymers, ob hom feem ntau yog thermoplastic thiab thermoset.

Q: Vim li cas tooj liab hlau npog los yog insulated nrog yas?

A: Cov hlua hluav taws xob siv hauv tsev feem ntau muaj cov yas lossis roj hmab npog kom tiv thaiv kev poob siab thaum peb kov lawv. Peb lub cev muaj peev xwm ua tau hluav taws xob, yog li thaum peb tuav cov xaim nqa tam sim no yam tsis muaj qhov npog, qhov tam sim no ntws los ntawm peb lub cev uas ua rau peb poob siab.

Q: Dab tsi yog tooj liab hlau npog?

A: Cov ntaub ntawv insulating feem ntau siv los npog tooj liab (thiab lwm yam) cov khoom siv hluav taws xob poob rau hauv ob chav kawm dav: Thermoplastic thiab Thermoset.

Q: Puas yog tooj liab hlau degrade raws sijhawm?

A: Tsis ntev los no tsim, tshiab liab qab tooj liab neeg xyuas pib ua hauj lwm zoo heev, tab sis liab qab tooj liab hlau yog nquag oxidation nyob rau hauv lub sij hawm ntau npaum li cas tshaj nws tinner counterpart. Oxidation ntawm liab qab hlau ua rau nws degradation thiab tsis ua hauj lwm nyob rau hauv hluav taws xob kev ua tau zoo.

Q: Koj yuav npog tooj liab li cas?

A: Lub hom phiaj tseem ceeb ntawm daim kab xev hluav taws xob yog los thaiv cov xov hlau. Nws yuav tiv thaiv koj cov circuits kom tsis txhob raug thaum kho lossis teeb tsa hauv qhov chaw sib txawv. Lawv tiv thaiv tau hluav taws kub. Qee zaum, koj tuaj yeem siv daim kab xev hluav taws xob los thaiv cov xov hlau uas nqa cov hluav taws xob siab.

Q: Vim li cas tooj liab hlau yuav tsum tau insulated?

A: Kev rwb thaiv tsev yog qhov tseem ceeb ntawm kev nyab xeeb rau txhua qhov hluav taws xob cable, muab qhov sib txawv ntawm cov khoom sib txawv tuaj yeem ua rau tooj liab tsis zoo. Piv txwv li, raug dej tuaj yeem ua rau cov xaim hluav taws xob corrode. Thaum corrosion tshwm sim, cov hlau nce nws qhov kev tiv thaiv, ua rau muaj cua sov tsim uas tuaj yeem ua rau hluav taws.

Q: Vim li cas tooj liab hlau coated?

A: Cov txheej txheem hlau feem ntau siv rau saum npoo ntawm ib tus neeg xaim hlua hauv cov khoom siv hluav taws xob los txhim kho cov khoom siv, txo oxidation (corrosion) lossis txhim kho cov khoom hluav taws xob ntawm cov khoom siv hluav taws xob ntau. Peb ntawm cov txheej txheem ntau tshaj plaws (plating) cov ntaub ntawv siv nrog tooj liab conductors yog tin, nyiaj thiab npib tsib xee.

Q: Puas yog tooj liab hlau muaj txheej txheej?

A: Hlau enamels yog siv rau ntawm tooj liab thiab txhuas puag ncig thiab tiaj tus xov hlau siv nyob rau hauv motors, transformers, generators thiab hluav taws xob ntsuas ntsuas. Lawv raug kho rau ntawm cov xov hlau nrog cua sov. Qhov tshwm sim txheej txheej tseem ceeb ntawm kev ua haujlwm yog hluav taws xob rwb thaiv tsev. Hlau enamels kuj tau piav qhia tias yog thawj qhov rwb thaiv tsev.

Q: Dab tsi tiv thaiv cov hlau tooj liab los ntawm kev puas tsuaj rau lub cev?

A: A 6 AWG lossis loj tooj liab, tooj liab-clad txhuas, los yog aluminium grounding electrode conductor raug rau lub cev puas tsuaj yuav tsum tau tiv thaiv nyob rau hauv nruj hlau conduit (RMC), intermediate hlau conduit (IMG), Teem caij 80 rigid polyvinyl chloride conduit (PVC) , reinforced thermosetting resin conduit Hom XW (RTRC-XW), hluav taws xob.

Q: Koj ua li cas tiv thaiv tooj liab hlau los ntawm corrosion?

A: Ib txoj hauv kev yooj yim thiab yooj yim los tiv thaiv tooj liab los ntawm tarnishing yog tshuaj tsuag lossis pleev xim nrog ib hom tshwj xeeb ntawm sealer. Cov sealer no feem ntau yog muaj nyob rau hauv kev ua lag luam thiab ua txoj haujlwm zoo heev ntawm kev khaws cov foob pob hluav taws ntawm cov tooj liab.

Q: Puas yog tooj liab xaim muaj kev nyab xeeb?

A: Tus neeg xyuas pib tuaj yeem arc mus rau lwm tus neeg xyuas pib lossis mus rau ib feem ntawm lub ntiaj teb, uas yuav ua rau lub rwb thaiv tsev puas ntxiv thiab muaj peev xwm pib hluav taws. Txawm hais tias ntev arcing tsis tshwm sim, qhov luv luv yuav ua rau muaj kev cuam tshuam tsis zoo vim tias lub fuse lossis MCB yuav ua haujlwm. Qhov no tuaj yeem ua rau txaus ntshai thiab.

Q: Koj tuaj yeem qhia qhov zoo ntawm tooj liab hlau?

A: Koj xav tau lub gadget hu ua ohmmeter los ntsuas qhov tsis kam ntawm cov hlau tooj liab. Ib qho me me tam sim no dhau los nrog kev pab ntawm ohmmeter, uas yog siv los ntsuas qhov poob qis. Koj tuaj yeem pom qhov kev tawm tsam yooj yim los ntawm daim ntawv thov ntawm Ohm Txoj Cai.

Q: Hom tooj liab zoo tshaj plaws yog dab tsi?

A: Oxygen-dawb tooj liab hlau muaj cov thermal thiab hluav taws xob conductivity, zoo corrosion kuj thiab solderability, thiab siab kub kuj, recrystallization, thiab workability ua rau nws haum rau daim ntaub ntawv uas xav tau siab durability thiab raug.

Cim npe nrov: daim ntawv npog tooj liab duab plaub hlau, Tuam Tshoj daim ntawv npog tooj liab duab plaub hlau manufacturers, lwm tus neeg, Hoobkas

Xa kev nug

(0/10)

clearall