admin@yaweitransformer.cn    +86-18651392209
Cont

Puas muaj lus nug?

+86-18651392209

Enameled Copper Rectangle Hlau

Enameled Copper Rectangle Hlau

Hlau thickness loj {{0}}a: 0.80-5.60 mm;
Tus neeg xyuas pib dav loj --- b: 2.00~ 16.00mm;
Tus neeg xyuas pib dav piv: 1.4: 1
Yog tias qhov kev xaiv tshwj xeeb yog nyob sab nraud ntawm qhov saum toj no, thov hu rau peb.
Xa kev nug

Khoom Taw qhia

cov khoom piav qhia

 

Enameled rectangular hlau yog ib txoj hlua winding uas tau kos los yog extruded los ntawm cov pas nrig tsis muaj pa oxygen lossis hluav taws xob puag ncig aluminium pas nrig los ntawm cov pwm ntawm cov lus qhia tshwj xeeb. Cov hlau liab qab yog annealed thiab softened, thiab ces pleev xim rau thiab ci ntau zaus. Feem ntau siv nyob rau hauv windings ntawm cov khoom siv hluav taws xob xws li transformers thiab reactors.

 

Cov txiaj ntsig ntawm Enameled Copper Wire

Enameled tooj liab hlau muaj ntau yam zoo. Tau kawg, cov xaim kev ua tau zoo kuj nyob ntawm cov chaw tsim khoom winding uas koj xaiv. Txawm li cas los xij, feem ntau hais lus, enameled tooj liab hlau muaj cov txiaj ntsig hauv qab no.

 

High Ductility:Copper alloy qhov elongation tus nqi ntawm 20 ~ 40 feem pua ​​​​ pab txhawb rau lub siab ductility ntawm enameled tooj liab xov hlau.

 

Tsawg Resistivity:Enameled tooj liab xov hlau muaj hluav taws xob tsis kam 1.68 npaug siab dua li cov tooj liab hlau cable.

 

Anti-Fatigue:Tooj liab tsis yooj yim tawg. Nws muaj qhov elasticity txog li 1.8 npaug siab dua aluminium.

 

Tsawg Voltage Loss:Qhov tsawg resistivity ntawm cov hlau tooj liab cia tib lub tam sim no ntws nyob rau hauv tib seem. Copper cables muaj ib tug me me voltage poob. Yog li, tib qhov kev sib kis tau zoo tuaj yeem ua kom zoo dua qhov hluav taws xob zoo.

 

Tsawg hluav taws xob poob:Ib zaug ntxiv, qhov tsis tshua muaj zog ntawm tooj liab ua rau qis hluav taws xob poob dua li cov xov hlau txhuas.

 

Tsawg Thaum tshav kub kub tiam:tooj liab enameled nyob ntawm tib seem, thiab nyob rau hauv tib lub tam sim no, tsim kom muaj cua sov tsawg tshaj li txhuas hlau. Yog li ntawd, cov enameled tooj liab hlau yog ua hauj lwm zoo dua.

 

Daim Ntawv Thov Ntawm Enamel Coated Copper Hlau

 

Electromagnetic Hlau Rau Tsav

Cov enamel coated tooj liab xov hlau rau motors mas siv QZ, QZY, QA thiab Q (ZY/XY). Nws muaj qhov zoo abrasion thiab hnyav tsis kam thiab muaj peev xwm ua haujlwm hauv huab cua nrog huab cua tsis kam mus rau qhov kub thiab txias heev. Cov tshuab hluav taws xob siv hluav taws xob siv ntau yam kev siv xws li kiv cua, twj, tshuab, khoom siv hauv tsev, cov cuab yeej hluav taws xob.

 

Electromagnetic Hlau Rau Compressor

Lub enamel coated tooj liab hlau rau compressors feem ntau siv Q(ZY/XY)-2/200. Cov hlau enameled muaj qhov xav tau siab ntawm qhov kub thiab txias ua haujlwm. Feem ntau, ib nrab xyoo kev xeem yuav tsum tau ua nyob rau hauv thaum ntxov theem, thiab saum npoo yuav tsum tau coated nrog cov roj tub yees.

 

Phaj Magnet Hlau

Phaj hlau nplaum hlau yog tsuas yog siv rau winding coils ntawm hluav taws xob tsheb, transformers, motors, generators thiab ntau yam khoom siv hluav taws xob. Nws muaj cov khoom siv hluav taws xob zoo heev, thermal stability, khawb tsis kam, hnyav ua haujlwm, zoo thermal dissipation kev ua tau zoo thiab siab magnetic teb efficiency thaum lub qhov txhab rau hauv lub kauj.

 

Electromagnetic Hlau Rau Hluav Taws Xob Tsheb

Enamelled tooj liab hlau rau EV feem ntau yog siv 180-240 degree ca enameled tooj liab hlau. Piv nrog rau cov hlau puag ncig, qhov zoo ntawm enameled ca hlau yog tias tsis muaj qhov sib txawv, qhov ntim efficiency loj, qhov chaw zoo dua qub, thiab lub cev muaj zog yog qhov me me thiab cov zis siab. Lub enameled ca hlau muaj kev sib txhuam coefficient tsawg thiab kev ua haujlwm zoo winding.

 

Anti-Corona Electromagnetic Hlau

Anti-corona square hlau nplaum tuaj yeem ua haujlwm tsis tu ncua hauv ib puag ncig ntawm 200 degrees. Ntxiv rau qhov ua tau zoo thaum tshav kub kub, tiv thaiv hluav taws xob thiab kev ua haujlwm siab, nws kuj muaj kev tiv thaiv zoo corona. Yog li ntawd, nws yog dav siv nyob rau hauv ntau zaus conversion ceev tswj motors, hoisting motors, elevator motors, thiab lwm yam.

 

Copper Hlau Sizing

 

Thaum koj tau xaiv txoj cai ntawm cov hlau tooj liab rau koj qhov project, nws yog lub sijhawm los loj nws kom tsim nyog! Koj tuaj yeem ua qhov no los ntawm kev ntsuas AWG (American Wire Gauge) lossis metric sizing systems xws li SWG (Standard Wire Gauge). AWG system yog siv nyob rau hauv North America, thaum lub metric system yog siv nyob rau hauv feem ntau lwm lub teb chaws nyob ib ncig ntawm lub ntiaj teb no.

Thaum xaiv qhov loj ntawm tooj liab hlau rau koj qhov project, muaj ntau yam los xav txog. Cov no suav nrog:

Ntev- Qhov ntev ntawm cov hlau yuav txiav txim siab npaum li cas qhov hluav taws xob tuaj yeem hloov mus los ntawm nws. Yog tias koj xav tau lub zog ntau dua, tom qab ntawd koj yuav tsum siv cov xaim tuab dua kom cov tam sim no tuaj yeem ntws los ntawm nws yam tsis muaj cua sov thiab ua rau koj cov khoom puas.

Thickness- Lub thickness txiav txim siab npaum li cas tam sim no tuaj yeem ntws los ntawm cov hlau. Piv txwv li, ib lub cable tuab yuav nqa tau ntau dua tam sim no dua li qhov nyias nyias tab sis kuj tseem yuav siv ntau qhov chaw uas yuav tsis zoo tagnrho yog tias qhov chaw txwv.

Qhov hluav taws xob- Ntau hom tooj liab hlau muaj qhov sib txawv qhov siab tshaj plaws uas txhais tau tias lawv yuav tsum muaj qhov loj me kom tsim nyog ua ntej txuas mus rau circuits.

Enameled Copper Rectangle Wire

Hlau Enameling txheej txheem

 

Bare Hlau Annealing.Annealing yog txheej txheem ntawm qhov kub thiab txias uas ua rau cov tooj liab soften thiab ua kom nws yooj yim dua.

Daim ntawv thov ntawm Enamel ntawm Hlau.Qhov no yog txheej txheem tseem ceeb heev ntawm enameling; Thaum lub sij hawm no, cov hlau yog them nrog enamel los ntawm ib tug enameling tuag nruab nrog ib tug calibrated qhov uas pours tus nqi ntawm enamel ntawm cov hlau tsim nyog kom tau ib tug raug polymerization.

Polymerization ntawm enamel.Cov xaim npog nrog qhov kom muaj nuj nqis ntawm cov kua enamel yog nkag mus rau hauv qhov cub. Nyob ntawd, nws yuav siv sij hawm qhov chaw nyob rau hauv cov kuab tshuaj evaporation theem thiab ces cov enamel polymerization ib. Txawm hais tias qhov cub kub tau teem rau qhov nruab nrab 600 - 700 degree , vim qhov cuam tshuam ntawm cov xaim ceev, cov enamel kub nce mus txog 250 - 300 degree . Cov theem no kav tsawg dua 1 sec. Nyob rau tiam kawg ntawm qhov cub. Cov txheej txheem no yog rov ua dua kom txog thaum lub thickness ntawm enamel ncav cuag.

Txias Ntawm Cov Hlau.Ua tsaug rau cov kiv cua loj, cua txias yog tsav ntawm cov hlau kom txo qhov kub kom qis dua 100 degree.

Daim ntawv thov ntawm External Lubricant.Cov txheej txheem no yog qhov tseem ceeb heev rau cov neeg siv kawg: qhov tseeb, cov xaim zoo-lubricated tso cai rau kev ua haujlwm zoo thaum lub sijhawm tsim cov tshuab windings.

Coils Winding.Thaum nws xaus cov hlau enameling, cov hlau yog sib sau ua ke rau hauv tshwj xeeb spools yuav tsum tau tom qab hnyav thiab muag.

 

Yuav ua li cas xaiv qhov zoo tshaj plaws Enameled Copper Hlau rau koj lub lag luam?

 

Hlau Gauge Matters

Thawj kauj ruam hauv kev xaiv txoj cai enameled tooj liab hlau yog xav txog nws qhov ntsuas. Hlau gauge hais txog lub thickness ntawm cov hlau. Thicker xov hlau muaj tus lej ntsuas qis dua thiab tuaj yeem nqa tam sim no ntau dua. Xyuas kom meej tias cov xov hlau ntsuas tau phim koj cov kev xav tau hluav taws xob tshwj xeeb.

Cov khoom siv rwb thaiv tsev

Enameled tooj liab xov hlau yog insulated los tiv thaiv hluav taws xob to. Kev xaiv cov khoom siv rwb thaiv tsev yog qhov tseem ceeb. Cov ntaub ntawv muaj xws li polyester, polyurethane, thiab polyimide. Koj qhov kev xaiv yuav tsum ua raws li cov xwm txheej ib puag ncig thiab hom kev thov cov hlau yuav raug siv rau.

Kev ntsuas kub

Xav txog qhov kub ntawm qhov uas koj cov hlau yuav ua haujlwm. Cov xov hlau sib txawv muaj qhov ntsuas kub sib txawv. Nws yog ib qho tseem ceeb uas yuav tau xaiv ib qho uas tuaj yeem tswj tau qhov kev khiav hauj lwm kub ntawm koj daim ntawv thov yam tsis muaj degradation.

Copper Txheej

Qhov zoo ntawm cov txheej tooj liab yog lwm qhov tseem ceeb. Cov xov hlau zoo tshaj plaws muaj cov txheej txheem zoo sib xws thiab du, uas ua kom muaj hluav taws xob zoo dua. Nrhiav cov xov hlau uas muaj cov txheej txheem sib xws kom tsis txhob muaj teeb meem tshwm sim.

Environmental Resistance

Nyob ntawm seb koj cov hlau yuav siv qhov twg, nws yuav raug rau ntau yam ib puag ncig xws li ya raws, tshuaj lom neeg, lossis kub heev. Xaiv ib lub xaim uas tiv taus cov ntsiab lus no kom ntseeg tau tias nws kav ntev.

Nqi thiab nyiaj txiag

Tus nqi yog ib txwm xav txog rau cov lag luam. Thaum koj yuav tsum tsom rau qhov zoo tshaj plaws, nws yog ib qho tseem ceeb kom nrhiav tau qhov sib npaug ntawm qhov zoo thiab koj cov peev nyiaj. Tsis txhob cuam tshuam rau qhov zoo los txiav cov nqi vim nws yuav ua rau muaj teeb meem hauv txoj kev.

Supplier Reputation

Lub koob npe nrov ntawm tus neeg muag khoom yog qhov tseem ceeb. Xyuas kom koj tau txais koj cov enameled tooj liab hlau los ntawm ib tus neeg muag khoom muaj npe nrov thiab ntseeg siab uas tuaj yeem muab koj cov khoom zoo thiab kev pabcuam rau cov neeg siv khoom.

Compatibility nrog cov khoom siv

Ua ntej txiav txim siab, xyuas kom meej tias cov xaim xaiv tau sib haum nrog koj cov khoom siv thiab cov tshuab uas twb muaj lawm. Cov teeb meem kev sib raug zoo tuaj yeem ua rau tsis muaj txiaj ntsig thiab lub sijhawm poob qis.

Durability thiab Longevity

Enameled tooj liab xov hlau yog kev nqis peev mus ntev rau koj txoj kev lag luam. Xaiv cov xov hlau uas paub txog lawv cov kav ntev thiab ntev kom txo tau cov nqi kho thiab hloov pauv hauv lub sijhawm ntev.

Customization Options

Qee zaum, koj lub lag luam yuav muaj cov kev cai tshwj xeeb. Nrhiav cov neeg muag khoom uas muaj kev xaiv kho kom haum rau cov xaim rau koj cov kev xav tau tshwj xeeb.

Kev pab txhawb nqa

Muaj kev nkag mus rau kev txhawb nqa los ntawm koj tus neeg muag khoom tuaj yeem muaj nuj nqis. Nws ua kom ntseeg tau tias koj muaj kev pab thiab kev taw qhia thaum xav tau, tshwj xeeb tshaj yog thaum cuam tshuam nrog cov haujlwm nyuaj.

 

Kev kho ntawm Enameled Copper Rectangle Wire

 

  1. Kev kuaj pom tsis tu ncua yog qhov tseem ceeb rau kev txheeb xyuas kev puas tsuaj ntawm rwb thaiv tsev, txheej txheej puas, lossis lwm yam teeb meem. Kev daws teeb meem tam sim ntawd tiv thaiv kev puas tsuaj ntxiv.
  2. Ntxuav cov hlau thiab ua kom tsis txhob muaj kab mob yog qhov tseem ceeb. Siv cov kev tu kom tsim nyog thiab cov khoom siv kom tsis txhob ua rau lub rwb thaiv tsev puas.
  3. Ua kom muaj kev tuav tau zoo, siv cov cuab yeej tsim nyog, thiab tsis txhob cuam tshuam rau qhov chaw hnyav tiv thaiv txheej txheej. Kov cov hlau nrog kev saib xyuas kom muaj kev ncaj ncees.
  4. Ua raws li kev ntsuas kom txaus kom txias, qhov cua, thiab siv cov rwb thaiv tsev kub siab dua tiv thaiv overheating. Saib xyuas qhov ntsuas kub kom tsis txhob cuam tshuam kev ua haujlwm ntawm cov hlau.
  5. Tsis tu ncua ntxuav cov hlau kom tsis txhob muaj kab mob thiab tiv thaiv nws los ntawm ya raws, tshuaj lom neeg, thiab kuab paug. Siv cov coatings los yog enclosures nyob rau hauv corrosive ib puag ncig.
  6. Tshawb xyuas kev puas tsuaj los ntawm kev vibration thiab kev ntxhov siab. Txhim kho cov qauv kev txhawb nqa, siv cov khoom siv vibration-damping, thiab siv cov txheej txheem kev pab cuam kom txo tau cov teebmeem no.

 

Kev Tiv Thaiv Kev Tiv Thaiv rau Enameled Copper Rectangle Wire

 

Xyuas kom ruaj khov thiab kev thauj mus los zoo:

Txhawm rau kom muaj kev ncaj ncees ntawm cov txheej txheem ntawm enamelled daim duab peb sab tooj liab, nws yog ib qho tseem ceeb uas yuav tsum tau ua tib zoo saib xyuas thaum lub sijhawm khaws cia thiab kev thauj mus los. Nco ntsoov khaws cov xaim nyob rau hauv qhov chaw txias, qhuav, thiab huv si kom tiv thaiv kom tsis txhob ya raws lossis kev sib cuag nrog cov khoom corrosive. Nws raug nquahu kom khaws cov xaim nyob rau hauv txoj hauj lwm ntsug ntawm racks lossis racks, kom ntseeg tau tias lawv tau txais kev txhawb nqa zoo kom tsis txhob muaj kev khoov ntau dhau los yog coiling uas yuav ua rau cov txheej txheej enamel puas.

 

Siv cov kev tiv thaiv:

Thaum ua hauj lwm nrog enamelled daim duab peb sab tooj liab, cov khoom siv tiv thaiv tus kheej (PPE) ua lub luag haujlwm tseem ceeb hauv kev tiv thaiv cov xwm txheej tsis tsim nyog. Thaum tuav cov hlau, nws raug nquahu kom hnav hnab looj tes tiv thaiv koj txhais tes ntawm cov npoo ntse thiab muaj peev xwm txiav. Tsis tas li ntawd, tsom iav kev nyab xeeb yuav tsum tau hnav los tiv thaiv koj ob lub qhov muag los ntawm cov khib nyiab ya los yog cov khoom thaum lub sij hawm txiav, stripping, los yog soldering txheej txheem.

 

Cov txheej txheem hlau Stripping:

Stripping lub enamel txheej los ntawm enamelled duab plaub tooj liab hlau yog feem ntau tsim nyog rau kev sib txuas hluav taws xob los yog soldering. Txawm li cas los xij, nws yog ib qho tseem ceeb uas yuav tsum tau ceev faj thaum tus txheej txheem no kom tsis txhob ua rau cov xaim puas tsuaj los yog ua rau koj tus kheej muaj kev phom sij rau kev noj qab haus huv. Thaum stripping cov hlau, xyuas kom siv cov cuab yeej tsim nyog xws li precision hlau strippers tsim tshwj xeeb rau enamelled hlau stripping. Cov cuab yeej no tau kho qhov tob tob, tso cai tshem tawm cov enamel yam tsis muaj kev puas tsuaj rau hauv qab tooj liab.

 

peb lub Hoobkas

2---

3---01

6---11

 

7---07

 

7---09

 

FAQ

Q: Puas yog enameled tooj liab hlau insulated?

A: Cov hlau nplaum hlau, tseem hu ua winding hlau lossis enameled hlau, yog tooj liab lossis txhuas hlau coated nrog cov rwb thaiv tsev nyias thiab yog ib qho tseem ceeb ntawm cov transformers, inductors, motors, thiab lwm yam khoom siv hluav taws xob. Cov enamel feem ntau yog ib zaj duab xis polymer uas muab cov txheej txheem nruj nruam ntawm rwb thaiv tsev.

Q: Dab tsi yog qhov zoo ntawm enamel coated tooj liab hlau?

A: Piv nrog rau cov hlau puag ncig, qhov zoo ntawm enameled ca hlau yog tias tsis muaj qhov sib txawv, lub ntim efficiency loj, qhov chaw zoo dua qub, thiab lub cev muaj zog yog me me thiab cov zis ntau. Lub enameled ca hlau muaj kev sib txhuam coefficient tsawg thiab kev ua haujlwm zoo winding.

Q: Puas tuaj yeem enameled tooj liab hlau tuaj yeem soldered?

A: Yog lawm, koj tuaj yeem ua cov hlau enameled, tab sis muaj qee cov kauj ruam tseem ceeb uas koj yuav tsum tau ua kom ntseeg tau tias muaj kev sib txuas zoo. Lub enamel txheej ntawm cov hlau yog ib qho insulator, thiab soldering yuav tsum tau tshem tawm los yog hlawv cov rwb thaiv tsev no ntawm cov ntsiab lus uas koj xav kom muaj kev sib txuas.

Q: Puas yog enameled tooj liab hlau hlau nplaum?

A: Lub Enameled Aluminium Wire, tseem hu ua hlau nplaum hlau, feem ntau yog hais txog ib qho txhuas lossis tooj liab xov hlau uas tau muab cov txheej txheem. Cov txheej nyias nyias ntawm rwb thaiv tsev no ua rau nws muaj txiaj ntsig zoo rau lub tsev transformers, motors, inductors, hard disk actuators, hais lus, electromagnets thiab lwm yam.

Q: Puas yog enameled tooj liab ua hluav taws xob?

A: Enamelled hlau yog tsim los ntawm tooj liab lossis qee zaus txhuas, ob qho tib si yog ib hom kev xaim hluav taws xob. Tooj liab yog cov conductive heev thiab siv nyob rau hauv ntau daim ntawv thov uas yuav tsum tau conduction ntawm hluav taws xob, xws li hluav taws xob thaiv.

Q: Yuav ua li cas koj solder enameled hlau?

A: Boil deb ntawm ib millimeter lossis 2 ntawm cov enamel yam tsis tau txiav cov hlau tawm ntawm lub spool.
solder kawg ntawm cov hlau mus rau qhov chaw tiv tauj taw tes ntawm PCB.
Coj cov hlau mus rau qhov chaw tiv tauj ntawm PCB thiab txiav kom ntev.
Khoov qhov kawg tshiab ntawm cov hlau deb ntawm PCB.

Q: Koj yuav ua li cas tshem tawm enamel txheej los ntawm tooj liab?

A: Kev Taw Qhia Scraping: Txoj kev no suav nrog kev siv cov cuab yeej ntse, xws li riam siv hluav taws xob lossis ntawv xuab zeb, txhawm rau txhawm rau tshem tawm cov enamel. Nws yuav tsum tau ib txhais tes khov kho kom tsis txhob txiav los ntawm cov hlau. Txoj kev no yog qhov zoo tshaj plaws rau kev ua haujlwm me me lossis kev ua haujlwm siab.

Q: Vim li cas siv enameled hlau?

A: Qhov no muab hluav taws xob rwb thaiv tsev thiab pab cov windings los ntawm luv luv-circuiting. Cov hlau enamels yuav tsum muaj cov tshuaj zoo heev thiab thermal kuj, yuav tsum ua raws li cov tooj liab lossis txhuas hlau, thiab muaj kev ruaj ntseg zoo heev.

Q: Puas yog enameled tooj liab hlau conductive?

A: Cov txheej txheej enamel tsis cuam tshuam rau cov xaim muaj peev xwm ua hluav taws xob, thiab nws tseem yog qhov kev xaiv zoo thiab muaj txiaj ntsig rau ntau yam kev siv hluav taws xob thiab hluav taws xob.

Q: Lub luag haujlwm ntawm enameled hlau yog dab tsi?

A: Enameled xov hlau yog cov caj qaum ntawm cov transformers, uas lawv pab nyob rau hauv kev sib kis ntawm hluav taws xob hluav taws xob ntawm coils. Lawv muaj peev xwm tiv taus cua sov thiab tswj hluav taws xob rwb thaiv tsev yog qhov tseem ceeb hauv daim ntawv thov no.

Q: Kuv yuav ua li cas thiaj paub yog tias kuv cov hlau yog enameled?

A: Yooj yim: khawb nws thaum kawg nrog lub cuab yeej hlau, xws li ob lub pliers, thiab pom tias muaj dab tsi flakes tawm. Yog hais tias nws zoo li ci liab qab tooj liab, tej zaum nws yog. Feem ntau cov enameled tooj liab yog tsawg kawg yog ob peb ntxoov tsaus dua li ci liab liab liab, txawm tias cov khoom nrog lub tsho "ntshiab" enamel.

Q: Dab tsi yog chav kawm kub ntawm enameled tooj liab hlau?

A: Chav Kawm A: Kev ntsuas kub: Txog 105 degree (221 degree F). Common Uses: Haum rau cov khoom siv hauv tsev dav dav, teeb pom kev zoo, thiab cov khoom siv uas qhov kub thiab txias tsis tshua muaj. Chav Kawm B: Kev ntsuas kub: Txog 130 degree (266 degree F).

Cim npe nrov: Tuam Tshoj enameled tooj liab duab plaub hlau, Tuam Tshoj enameled tooj liab duab plaub hlau manufacturers, lwm tus neeg, Hoobkas

Xa kev nug

(0/10)

clearall